XDF 1.110000 DO NOT HAND EDIT!!!! (Trust me) %%HEADER%% 001000 FileVers ="2" 001005 DefTitle ="NVMG8" 001007 DescSize =0xF1 001006 Desc ="Covers 6DFC, 6DFD, 6DGC, 6DGD, Australian EL V8 5ltr ecu's from 1996-1998, and could cover more that Ive not yet tested. \r\nRequires 64k bin file, first 0x2000 to be 'padded' with null data. Not all parameters defined have been tested yet." 001010 Author ="Jaysen Anderson" 001030 BinSize =0x10000 001035 BaseOffset =0 001200 ADSAssoc ="" 001225 ADSCheck =0x0 001300 GenFlags =0x0 001325 ModeFlags =0x0 002000 Category0 ="Fuel" 002001 Category1 ="Spark" 002002 Category2 ="Sensors" 002003 Category3 ="Limits" 002004 Category4 ="Miscellaneous" 002005 Category5 ="Idle" 002006 Category6 ="Hardware" 002007 Category7 ="Scalers" 002008 Category8 ="Tests" 002009 Category9 ="Adaptive Learning" 002010 Category10 ="Failure Management" 002011 Category11 ="EGR" 002012 Category12 ="Purge" 002013 Category13 ="Accessories" 002014 Category14 ="Economy Mode" 002015 Category15 ="Transmission" 002016 Category16 ="Cruise Control" 002017 Category17 ="Transient Fuel" 002018 Category18 ="Unknown" 002019 Category19 ="Unknown" %%END%% %%CONSTANT%% 000002 UniqueID =0x5938 000100 Cat0ID =0x9 020005 Title ="**A/F Ratio for Goose Test" 020011 DescSize =0xB 020010 Desc ="V_KNK_FUEL" 020020 Units ="A/F Ratio" 020050 SizeInBits =0x10 020100 Address =0xA3E8 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4B2D 000100 Cat0ID =0x9 020005 Title ="**A/F Ratio for Self Test" 020011 DescSize =0x6 020010 Desc ="VRLAM" 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0xB490 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x38A7 000100 Cat0ID =0x9 020005 Title ="**A/F Ratio Rich Limit" 020011 DescSize =0x44 020010 Desc ="REQV - Desired A/F ratio is clipped to this limit during self test." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0xB48C 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4D1 000100 Cat0ID =0x9 020005 Title ="**A/F Ratio Lean Limit" 020011 DescSize =0x44 020010 Desc ="LEQV - Desired A/F ratio is clipped to this limit during self test." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0xB48E 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x114E 000100 Cat0ID =0x1 020005 Title ="**Accel Enrichment Global Multiplier" 020011 DescSize =0xAD 020010 Desc ="AEM - A multiplier of the result of the 'Accel Enrichment Fuel' (aka FN1303) table lookup.\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 020020 Units ="multiplier" 020100 Address =0xA4F6 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1EA2 000100 Cat0ID =0x5 020005 Title ="**Accel Enrichment Load Time Constant" 020011 DescSize =0xEA 020010 Desc ="TCAELD - The time constant for the rolling average calculation of the 'Accel Enrichment Load' (aka AELOAD) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADD4 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x96E 000100 Cat0ID =0x1 020005 Title ="**Accel Enrichment Minimum" 020011 DescSize =0x31 020010 Desc ="MINAE\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xB0AA 020150 Flags =0x2 020200 Equation =X/262144,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x527F 000100 Cat0ID =0x1 020005 Title ="**Accel Enrichment Min Delta Load" 020011 DescSize =0x51 020010 Desc ="AEACLD - The change in load required to indicate the intake manifold is filling." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xA4FC 020150 Flags =0x3 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5544 000100 Cat0ID =0x1 020005 Title ="**Accel Enrichment Min Throttle Rate" 020011 DescSize =0x67 020010 Desc ="AETAR - The rate of throttle change must be greater than this value to enable acceleration enrichment." 020020 Units ="deg/sec" 020100 Address =0xA4FE 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2C34 000100 Cat0ID =0x11 020005 Title ="**Acceleration Ramp Rate" 020011 DescSize =0x4F 020010 Desc ="ACLINC - The rate of acceleration from the current speed to the desired speed." 020020 Units ="mph/sec" 020050 SizeInBits =0x10 020100 Address =0xA312 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x556F 000100 Cat0ID =0x1 020005 Title ="**ACT Fraction for Accel Enrichment" 020011 DescSize =0x187 020010 Desc ="FRCTAE - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Accel Enrichment Fuel Scaler for ACT to ECT' (aka FN020B) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0xA4FF 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5BA0 000100 Cat0ID =0x2 020005 Title ="**ACT Fraction for Base Dwell" 020011 DescSize =0x1CC 020010 Desc ="DWLWF - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the calculation of the estimated coil temperature value. This estimated value is checked against the 'Dwell Time Table Select Temperature' (aka DWLTMP) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0xAA28 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5540 000100 Cat0ID =0x12 020005 Title ="**ACT Fraction for Transient Fuel" 020011 DescSize =0x174 020010 Desc ="ALPHA - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0xA4F4 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x35AA 000100 Cat0ID =0x1 020005 Title ="**ACT Fraction for Fuel Base Table" 020011 DescSize =0x175 020010 Desc ="FRCBFT - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0xB0B7 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5296 000100 Cat0ID =0x1 020005 Title ="**ACT Fraction for Fuel Startup Table" 020011 DescSize =0x175 020010 Desc ="FRCSFT - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0xB0B8 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7A52 000100 Cat0ID =0x1 020005 Title ="**ACT Fraction for Spark" 020011 DescSize =0x35 020010 Desc ="FRCSPK - \r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="multiplier" 020100 Address =0xAA0F 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D2D 000100 Cat0ID =0x9 020005 Title ="**ACT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VIACT2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA3DA 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3442 000100 Cat0ID =0x9 020005 Title ="**ACT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VIACT1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA3D8 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29F0 000100 Cat0ID =0x9 020005 Title ="**ACT KOER Max" 020011 DescSize =0x7 020010 Desc ="VIACT4" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA3DE 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2C28 000100 Cat0ID =0x9 020005 Title ="**ACT KOER Min" 020011 DescSize =0x7 020010 Desc ="VIACT3" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA3DC 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7563 000100 Cat0ID =0x4 020005 Title ="**ACT Max" 020011 DescSize =0x53 020010 Desc ="ACTMAX - Value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA33E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5153 000100 Cat0ID =0x4 020005 Title ="**ACT Min" 020011 DescSize =0x54 020010 Desc ="ACTMIN - Value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA33C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x362D 000100 Cat0ID =0x12 020005 Title ="**Actual Intake Surface Fuel Multiplier" 020011 DescSize =0x61 020010 Desc ="AISFM - Multiplier of 'Actual_Intake_Surface_Fuel' (aka AISF) during deceleration fuel shut off." 020020 Units ="multiplier" 020100 Address =0xB0C6 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4F4D 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control Accel Enrichment Max" 020011 DescSize =0x69 020010 Desc ="AELIM - The maximum acceleration enrichment fuel flow permitted in order for adaptive learning to occur." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xB0F4 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x61CC 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control ACT Max" 020011 DescSize =0x7 020010 Desc ="AFACT2" 020020 Units ="deg F" 020100 Address =0xB0E9 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x619D 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control ACT Min" 020011 DescSize =0x7 020010 Desc ="AFACT1" 020020 Units ="deg F" 020100 Address =0xB0E8 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4DA7 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control Deadband" 020011 DescSize =0x335 020010 Desc ="DELAMB - This value is used to form the deadband around stoichiometric within which the adaptive learning loop counter values are not altered.\r\n\r\nWhen the HEGO is reporting a rich condition this parameter's value is added to the resultant value created by adding the HEGO Bias value to the stoichiometric A/F ratio to establish a lean A/F ratio which if greater than the lean 'Desired A/F Ratio' (aka LAMBSE) value being commanded then the loop counter incrementing does not occur.\r\n\r\nWhen the HEGO is reporting a lean condition this parameter's value is subtracted from the resultant value created by adding the HEGO Bias value to the stoichiometric A/F ratio to establish a rich A/F ratio which if less than the rich 'Desired A/F Ratio' (aka LAMBSE) value being commanded then loop counter incrementing does not occur." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0xB0EC 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2274 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control Delay Time" 020011 DescSize =0xCD 020010 Desc ="ADAPTM - The time delay before adaptive learning is permitted once the ECT is between the values set by the 'Adaptive Control ECT Min' (aka AFECT1) and 'Adaptive Control ECT Max' (aka AFECT2) parameters." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xB0EA 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2AF1 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control ECT Max" 020011 DescSize =0xBD 020010 Desc ="AFECT2 - Temperature at which the 'Adaptive Fuel Timer' (aka ADPTMR) is reset to zero.\r\n\r\nSee 'Adaptive Control Delay Time' (aka ADAPTM) for more information on how this parameter is used." 020020 Units ="deg F" 020100 Address =0xB0E7 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3DA 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control ECT Min" 020011 DescSize =0xB8 020010 Desc ="AFECT1 - Temperature at which the 'Adaptive Fuel Timer' (aka ADPTMR) is started.\r\n\r\nSee 'Adaptive Control Delay Time' (aka ADAPTM) for more information on how this parameter is used." 020020 Units ="deg F" 020100 Address =0xB0E6 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6265 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control Fast HEGO Count" 020011 DescSize =0xE8 020010 Desc ="FAEGCT - The minimum number of HEGO counts required for adaptive learning to take place when the number of KAM warm ups is less than the 'Adaptive Control Max Warm Up Cycles' value. Lower values increase the adaptive learning rate." 020020 Units ="counts" 020100 Address =0xB0FB 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x68D7 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control Max" 020011 DescSize =0x39 020010 Desc ="MAXADP - The maximum value that KAMREF is allowed to be." 020020 Units ="multiplier" 020100 Address =0xB0F3 020150 Flags =0x8 020200 Equation =(X/256)+0.5,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x6266 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control Max Warm Up Cycles" 020011 DescSize =0x91 020010 Desc ="KWUCNT - The maximum number of warm up cycles to use the faster adaptive learning update rate. Beyond this value the normal update rate is used." 020020 Units ="no." 020100 Address =0xB0FC 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4904 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control Min" 020011 DescSize =0x39 020010 Desc ="MINADP - The minimum value that KAMREF is allowed to be." 020020 Units ="multiplier" 020100 Address =0xB0F2 020150 Flags =0x8 020200 Equation =(X/256)+0.5,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x44DB 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control Table Column Lockout" 020011 DescSize =0x124 020010 Desc ="DELCOL - If the difference between the current adaptive control learning table column (aka NRMCES) and the last adaptive control learning table column (aka LSTCOL) is greater than this value then adaptive learning is disabled. Used to reduce the effect of excessive transient changes in rpm." 020020 Units ="column" 020050 SizeInBits =0x10 020100 Address =0xB0F0 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x40E3 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control Table Row Lockout" 020011 DescSize =0x11F 020010 Desc ="DELROW - If the difference between the current adaptive control learning table row (aka NRMRLD) and the last adaptive control learning table row (aka LSTROW) is greater than this value then adaptive learning is disabled. Used to reduce the effect of excessive transient changes in load." 020020 Units ="row" 020050 SizeInBits =0x10 020100 Address =0xB0EE 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x46B4 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control Normal HEGO Count" 020011 DescSize =0xB9 020010 Desc ="ADEGCT - The minimum number of HEGO counts required for adaptive learning to take place when the number of KAM warm ups is greater than the 'Adaptive Control Max Warm Up Cycles' value." 020020 Units ="counts" 020100 Address =0xB0FA 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x285A 000100 Cat0ID =0xA 020005 Title ="**Adaptive Control Transient Fuel Max" 020011 DescSize =0x6E 020010 Desc ="ADEFTR - The maximum transient fuel compensation fuel flow permitted in order for adaptive learning to occur." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xB0F8 020150 Flags =0x3 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x7EE9 000100 Cat0ID =0xE 020005 Title ="**Adjustable Damper Min TP" 020011 DescSize =0x51 020010 Desc ="SHKTP - The minimum voltage above closed throttle to indicate hard acceleration." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9412 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5599 000100 Cat0ID =0xB 020005 Title ="**Airmass Flow Min For TP Calculation" 020011 DescSize =0xCE 020010 Desc ="IDLMAF - If the airmass is less than this then the eec sets the throttle value equal to the closed throttle value if either the TPS has failed, is less than 'TPS Max' value or greater than 'TPS Max' value." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA97A 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x45FE 000100 Cat0ID =0xA 020005 Title ="**Allow Adaptive Learning" 020011 DescSize =0xA8 020010 Desc ="Z_ADPSW - Set to \"4700\" to permit adaptive learning to occur, change to \"480F\" to disable adaptive learning.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x1B4 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x24BA 000100 Cat0ID =0x9 020005 Title ="**AM2 Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT1 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA40A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5C4 000100 Cat0ID =0x9 020005 Title ="**AM1 Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT2 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA40C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E0B 000100 Cat0ID =0x7 020005 Title ="Auxiliary Hardware Present" 020011 DescSize =0xD0 020010 Desc ="THRMHP - The four possible settings are;\r\n\r\n0 = None of the following hardware is present\r\n1 = Thermactor hardware present\r\n2 = Supercharger bypass valve present\r\n3 = Inlet manifold air control valve present" 020020 Units ="" 020100 Address =0xB46D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3492 000100 Cat0ID =0x9 020005 Title ="Battery Voltage Lower Limit" 020011 DescSize =0xA 020010 Desc ="VKYPWR - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA326 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6130 000100 Cat0ID =0x5 020005 Title ="Battery Voltage Time Constant" 020011 DescSize =0xE2 020010 Desc ="TCVBAT - The time constant for the rolling average calculation of the 'Battery Voltage' (aka VBAT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADD0 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6B6E 000100 Cat0ID =0x9 020005 Title ="BP Max During Test" 020011 DescSize =0x7 020010 Desc ="VBPDL2" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0xA3EC 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xC47 000100 Cat0ID =0x9 020005 Title ="BP Max Time Between Update" 020011 DescSize =0x7 020010 Desc ="VBPMAX" 020020 Units ="secs" 020100 Address =0xA3FE 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3AF5 000100 Cat0ID =0x9 020005 Title ="BP Min During Test" 020011 DescSize =0x7 020010 Desc ="VBPDL1" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0xA3EA 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x60A6 000100 Cat0ID =0x3 020005 Title ="BP Time Constant" 020011 DescSize =0xF2 020010 Desc ="TCBBAR - The time constant for the rolling average calculation of the 'BP' (aka BP) and 'BP Average' (aka BAPBAR) values.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADD6 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x530D 000100 Cat0ID =0x11 020005 Title ="Buttons Not Pressed Maximum" 020011 DescSize =0x60 020010 Desc ="HIHOLD - Highest value of Vehicle Speed Control Command Switch to indicate no button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E80 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52E0 000100 Cat0ID =0x11 020005 Title ="Buttons Not Pressed Minimum" 020011 DescSize =0x5F 020010 Desc ="LOHOLD - Lowest value of Vehicle Speed Control Command Switch to indicate no button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E7E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xF37 000100 Cat0ID =0x6 020005 Title ="Buzz RPM" 020011 DescSize =0x53 020010 Desc ="BZZRPM - Additional rpm added to base target idle rpm at start up to clear engine." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA542 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6BCB 000100 Cat0ID =0x6 020005 Title ="Buzz RPM Time" 020011 DescSize =0x7C 020010 Desc ="BZZTM - Duration that 'Buzz RPM' (aka BZZRPM) is added to base target idle rpm at startup. \r\n\r\nConversion to be determined." 020020 Units ="secs" 020100 Address =0xA55B 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x56A5 000100 Cat0ID =0x1 020005 Title ="C/L Neutral Idle Fuel Max Time" 020011 DescSize =0xE9 020010 Desc ="NIOLD - If the 'Close Throttle Neutral Timer' (aka CTNTMR) exceeds this value then open loop mode is used when in neutral at idle. This value is only checked by the eec when at closed throttle. Set to '255' to disable this function." 020020 Units ="secs" 020100 Address =0xA53C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E9E 000100 Cat0ID =0x9 020005 Title ="Canister Purge Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT5 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA412 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x13DF 000100 Cat0ID =0xD 020005 Title ="Canister Purge Min RPM" 020011 DescSize =0x44 020010 Desc ="EVRPM - \r\n\r\nDoes not appear to be used by the eec in this strategy." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA946 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6A19 000100 Cat0ID =0xD 020005 Title ="Canister Purge Min RPM Hysteresis" 020011 DescSize =0x45 020010 Desc ="EVRPMH - \r\n\r\nDoes not appear to be used by the eec in this strategy." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA948 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x131E 000100 Cat0ID =0x5 020005 Title ="Checksum" 020011 DescSize =0x9F 020010 Desc ="CHKSUM - Do not edit. This is recalculated automatically when the bin is saved. When emulating, upload this new checksum to the emulator after saving the bin." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x200A 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7F06 000100 Cat0ID =0xA 020005 Title ="Clear KAM" 020011 DescSize =0x1C6 020010 Desc ="Z_KAMCLR - Forces the re-initialisation of the Keep Alive Memory so that all adaptive learning information is cleared.\r\n\r\nNormally set to \"235D\", change this to \"2382\" to clear the KAM (either during running if your emulator permits 'on the fly' changes or by cycling the key to 'run' and then off) and then restore back to the original value. Does not affect the KAM during KOEO or KEOR tests.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x18C 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DB 000100 Cat0ID =0x11 020005 Title ="Coast Button Maximum" 020011 DescSize =0x5D 020010 Desc ="HCOAST - Highest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E74 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DA 000100 Cat0ID =0x11 020005 Title ="Coast Button Minimum" 020011 DescSize =0x5C 020010 Desc ="LCOAST - Lowest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E72 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x32B1 000100 Cat0ID =0x1 020005 Title ="Cold Engine Fuel Multiplier Update Time Limit" 020011 DescSize =0xEC 020010 Desc ="MULTM - When the 'Cold Engine Fuel Multiplier Update Timer' (aka MULTMR) exceeds this value then the 'Cold Engine Fuel Multiplier' (aka LAMMUL) value is updated.\r\n\r\nDoes not appear to be used in this ecu, possibly superseded by FN393F." 020020 Units ="secs" 020100 Address =0xB0FD 020150 Flags =0x8 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x3367 000100 Cat0ID =0x5 020005 Title ="Cold Start Max ECT" 020011 DescSize =0x45 020010 Desc ="CTLOW - The maximum ECT for a cold start condition to be recognised." 020020 Units ="deg F" 020100 Address =0xB467 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6082 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Exit Min PIPs" 020011 DescSize =0xD7 020010 Desc ="NCNT - Once the ECT sensor has been read 8 times this is the minimum number of PIPs that must occur once the rpm is greater than the 'Cranking Mode Exit Min RPM' (aka NRUN) parameter in order to exit cranking mode." 020020 Units ="no." 020100 Address =0xAD92 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5D9D 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Exit RPM" 020011 DescSize =0xC2 020010 Desc ="NRUN - Once the ECT sensor has been read 8 times this is the minimum rpm required for the 'Cranking Mode Exit Min PIPs' (aka NCNT) parameter to be checked to see if cranking mode can be exited." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xAD98 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x128C 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Re-enter RPM" 020011 DescSize =0x4E 020010 Desc ="NSTALL - If the rpm is less than this value then cranking mode is re-entered." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xAD9A 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x34AF 000100 Cat0ID =0x2 020005 Title ="Cranking Mode Spark" 020011 DescSize =0x137 020010 Desc ="Z_CRKSPK - The spark advance used during cranking. Adjust for highly modified engines that will not start with the stock advance value of 10 degrees.\r\n\r\nRequires the use of a \"black\" Computer Controlled Dwell (CCD) TFI module and the 'Computer Controlled Dwell Present' (aka CCDSW) parameter needs to be set.\r\n" 020020 Units ="deg adv" 020100 Address =0x55CA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x56A6 000100 Cat0ID =0x1 020005 Title ="CT Neutral Timer Hysteresis" 020011 DescSize =0x84 020010 Desc ="NIHYS - Added to 'C/L Neutral Idle Fuel Max Time' to make the upper clip limit of the 'Closed Throttle Neutral Timer' (aka CTNTMR)." 020020 Units ="secs" 020100 Address =0xA53D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x583C 000100 Cat0ID =0x5 020005 Title ="CT Neutral Timer Max RPM" 020011 DescSize =0xF3 020010 Desc ="INLRPM - The base rpm added to the result of the 'CT Neutral Timer RPM Adder' (aka FN880) lookup. This resultant value is the maximum rpm allowed in order for the 'CT Neutral Timer' to count up and the 'CT Neutral Flag (aka CTNFLG) to be set." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA92E 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7C1 000100 Cat0ID =0x5 020005 Title ="CT Neutral Timer Max RPM Hysteresis" 020011 DescSize =0x4B 020010 Desc ="INLRPH - Hysteresis for the 'CT Neutral Timer Max RPM' (aka INLRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA930 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5C04 000100 Cat0ID =0x2 020005 Title ="CT Tip In Flag Min Load" 020011 DescSize =0x56 020010 Desc ="TIPLOD - The minimum load in order for the closed throttle tip in flag to be cleared." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xAA32 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x257B 000100 Cat0ID =0x2 020005 Title ="CT Tip In Flag Min Load Hysteresis" 020011 DescSize =0x3D 020010 Desc ="TIPHYS - Hysteresis for the 'CT Tip In Flag Min Load' value." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xAA34 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2B9F 000100 Cat0ID =0x9 020005 Title ="CT to PT Transitions to Enable HEGO Switch Test" 020011 DescSize =0x7 020010 Desc ="VPTCNT" 020020 Units ="no." 020100 Address =0xA37D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5A6E 000100 Cat0ID =0x2 020005 Title ="CT Spark Adder" 020011 DescSize =0x30 020010 Desc ="KCS1 - Added to 'CT Spark vs RPM' lookup value." 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0xA980 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x35EF 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Desired AF Ratio" 020011 DescSize =0x7 020010 Desc ="VLAMCB" 020020 Units ="AF ratio" 020050 SizeInBits =0x10 020100 Address =0xA370 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7D76 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Desired RPM" 020011 DescSize =0xA 020010 Desc ="VISCN1 - " 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA372 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1CA8 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Injector Off Time" 020011 DescSize =0x7 020010 Desc ="VCBTM2" 020020 Units ="secs" 020100 Address =0xA379 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3D8A 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Injector On Time" 020011 DescSize =0x7 020010 Desc ="VCBTM1" 020020 Units ="secs" 020100 Address =0xA378 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A03 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop" 020011 DescSize =0x7 020010 Desc ="VCBPCT" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0xA36E 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7730 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Clip" 020011 DescSize =0x7 020010 Desc ="VCBCLP" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0xA36A 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1BC6 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Increment" 020011 DescSize =0x7 020010 Desc ="VCBPAD" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0xA36C 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1B08 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Time" 020011 DescSize =0x7 020010 Desc ="VISDL5" 020020 Units ="secs" 020100 Address =0xA377 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x540 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Start Delay" 020011 DescSize =0x7 020010 Desc ="VCBDLY" 020020 Units ="secs" 020100 Address =0xA374 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x377C 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Time Wait" 020011 DescSize =0x7 020010 Desc ="VISDL4" 020020 Units ="secs" 020100 Address =0xA376 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x41FF 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Type" 020011 DescSize =0x54 020010 Desc ="VCBFLG -\r\n\r\n-1 = allow test\r\n 0 = inhibit test\r\n 1 = allow multiple entries to test" 020020 Units ="state" 020100 Address =0xA375 020150 Flags =0x1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5377 000100 Cat0ID =0x6 020005 Title ="Dashpot Min for Declutch" 020011 DescSize =0x12B 020010 Desc ="DASMIN - When at closed throttle this is the minimum dashpot (pre position airflow) allowed when the vehicle speed is greater than the resultant value created by adding the 'Dashpot Min MPH for Declutch' (aka DASMPH) and 'Dashpot Min MPH for Declutch Hysteresis' (aka DASMHYST) parameters together." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA31E 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5375 000100 Cat0ID =0x6 020005 Title ="Dashpot Min MPH for Declutch" 020011 DescSize =0xD6 020010 Desc ="DASMPH - When the 'Dashpot Min for Declutch' (aka DASMIN) parameter is being used by the eec this is the minimum vehicle speed required for this minimum dashpot (pre position airflow) to be continue to be applied." 020020 Units ="mph" 020100 Address =0xA31B 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5376 000100 Cat0ID =0x6 020005 Title ="Dashpot Min MPH for Declutch Hysteresis" 020011 DescSize =0x55 020010 Desc ="DASMHYST - Hysteresis for the 'Dashpot Min MPH for Declutch' (aka DASMPH) parameter." 020020 Units ="mph" 020100 Address =0xA31C 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x563E 000100 Cat0ID =0x6 020005 Title ="Dashpot Offset" 020011 DescSize =0xA7 020010 Desc ="DASPTO - An offset added to the final dashpot (pre position airflow) value in order to ensure some airflow during tip in or tip out. Typically set around 0.10 lb/min." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA528 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x563F 000100 Cat0ID =0x6 020005 Title ="Dashpot TP" 020011 DescSize =0xCD 020010 Desc ="DELHYS - Used in the calculation of the dashpot (pre position airflow) value. Set equal to the sum of the following parameters;\r\n\r\n'TPS PT Threshold' (aka DELTA)\r\n'TPS PT Threshold Hysteresis' (aka HYSTS)" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA52A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x530E 000100 Cat0ID =0x11 020005 Title ="DC Correction Factor" 020011 DescSize =0x7 020010 Desc ="DCBIAS" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8E82 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x26B0 000100 Cat0ID =0x11 020005 Title ="Debounce Time Delay" 020011 DescSize =0x7 020010 Desc ="DEBTIM" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8E8A 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x51C8 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off CT Min Time Delay" 020011 DescSize =0x10A 020010 Desc ="CTDFSO - The minimum time delay required for deceleration fuel shut off to be permitted when the throttle is closed.\r\nSet to less than the 'Decel Fuel Shut Off Time Delay Extension' (aka CTEDSO) value.\r\nNot used if the 'Decel Fuel Shut Off PT Enable' switch is set." 020020 Units ="secs" 020100 Address =0xB0D2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x788E 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Fuel Ramp Back Clip" 020011 DescSize =0x4B 020010 Desc ="DMIN - A clip applied to FN379.\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="???" 020050 SizeInBits =0x10 020100 Address =0xB0DC 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3271 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Timer Run" 020011 DescSize =0x5B 020010 Desc ="DFLDL - The maximum load allowed for the 'Decel Fuel Shut Off Low Load Timer' to count up." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xB0E0 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5DB7 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Timer Stop" 020011 DescSize =0x5D 020010 Desc ="DFLDH - The minimum load required for the 'Decel Fuel Shut Off Low Load Timer' to be reset." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xB0E2 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x137B 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Time" 020011 DescSize =0xA 020010 Desc ="DLDFSO - " 020020 Units ="secs" 020100 Address =0xB0E4 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A83 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Max Load" 020011 DescSize =0x51 020010 Desc ="DFLOD - The maximum load allowed for deceleration fuel shut off to be permitted." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xB0C8 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2FD3 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Max Load Hysteresis" 020011 DescSize =0x42 020010 Desc ="DFLODH - Hysteresis for the 'Decel Fuel Shut Off Max Load' value." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xB0CA 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x73E5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min ECT" 020011 DescSize =0x9F 020010 Desc ="DFSECT - The minimum ECT required for deceleration fuel shut off to be permitted prior to the 'Decel Fuel Shut Off Time Delay' (aka AGB) value being exceeded." 020020 Units ="deg F" 020100 Address =0xB0C7 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6278 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min MPH" 020011 DescSize =0x5B 020010 Desc ="DFSVS - The minimum vehicle speed required for deceleration fuel shut off to be permitted." 020020 Units ="mph" 020100 Address =0xB0DE 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x24A5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min MPH Hysteresis" 020011 DescSize =0x4D 020010 Desc ="DFSVSH - Hysteresis for the 'Decel Fuel Shut Off Min MPH' (aka DFSVS) value." 020020 Units ="mph" 020100 Address =0xB0DF 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x49D0 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min PIP To Remain O/L" 020011 DescSize =0x101 020010 Desc ="PIPNUM - After deceleration fuel shut off has finished this is the number of PIPs that must occur in order to stay in open loop mode. This prevents the desired AF ratio from ramping rich until the HEGO transport delay has passed. Set to 1 to calibrate out." 020020 Units ="pips" 020100 Address =0xB0D5 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E3A 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min RPM" 020011 DescSize =0x66 020010 Desc ="DFSRPM - The minimum rpm above the desired idle rpm at which deceleration fuel shut off is permitted." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB0CC 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6056 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min RPM Hysteresis" 020011 DescSize =0x4E 020010 Desc ="DFSRPH - Hysteresis for the 'Decel Fuel Shut Off Min RPM' (aka DFSRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB0CE 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x8F5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min Time at PT" 020011 DescSize =0xC4 020010 Desc ="DSFTM - The minimum time at part or wide open throttle required for deceleration fuel shut off to be permitted after the 'Decel Fuel Shut Off CT Min Time Delay' has occurred.\r\n\r\nNeeds confirming." 020020 Units ="secs" 020100 Address =0xB0D4 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x10B 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Neutral Max Time" 020011 DescSize =0x9A 020010 Desc ="DSTM1 - The maximum time that deceleration fuel shut off is permitted during deceleration whilst in neutral.\r\nOnly used if 'Transmission Type' is 2 or 3." 020020 Units ="secs" 020100 Address =0xB0D0 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x186C 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Max Time" 020011 DescSize =0x75 020010 Desc ="DSTM2 - The maximum time that deceleration fuel shut off is permitted during gear shifts on manual gearbox vehicles." 020020 Units ="secs" 020100 Address =0xB0D1 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x656 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min RPM" 020011 DescSize =0xAE 020010 Desc ="SHFRPM - The minimum rpm above the 'Desired Idle RPM' (aka DSDRPM) required for the deceleration fuel shut off to be permitted during gear shifts on manual gearbox vehicles." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB0D8 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2F 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min RPM Hysteresis" 020011 DescSize =0x54 020010 Desc ="SHFHYS - Hysteresis for the 'Decel Fuel Shut Off Shift Min RPM' (aka SHFRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB0DA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x3E60 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min TP Hysteresis" 020011 DescSize =0x34 020010 Desc ="TPHYS - \r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xB0D6 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x772 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Time Delay" 020011 DescSize =0xC4 020010 Desc ="AGB - The minimum time that must elapse after exiting crank in order for deceleration fuel shut off to be permitted when the ECT is less than the 'Decel Fuel Shut Off Min ECT' (aka DFSECT) value." 020020 Units ="secs" 020100 Address =0xA4D7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1D75 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Time Extension" 020011 DescSize =0x13E 020010 Desc ="CTEDSO - Used to keep deceleration fuel shut off continuing during long decelerations (such as lengthy descents) even if short tip in/tip out events occur.\r\nSet to greater than the 'Decel Fuel Shut Off CT Min Time Delay' (aka CTDFSO) value.\r\nNot used if the 'Decel Fuel Shut Off PT Enable' (aka PTDFSW) switch is set." 020020 Units ="secs" 020100 Address =0xB0D3 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3998 000100 Cat0ID =0xB 020005 Title ="Default ACT" 020011 DescSize =0x6C 020010 Desc ="ACTFMM - Default value used for ACT when the ACT sensor has failed and (other conditions to be determined)." 020020 Units ="deg F" 020100 Address =0xA975 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x182E 000100 Cat0ID =0x5 020005 Title ="Default BAP" 020011 DescSize =0x4E 020010 Desc ="KONBP - Default barometric pressure value used when no BAP sensor is fitted.." 020020 Units ="in Hg" 020100 Address =0xAA4A 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6F57 000100 Cat0ID =0xB 020005 Title ="Default BAP for Sensor Fail" 020011 DescSize =0x50 020010 Desc ="BAPFMM - Default barometric pressure value used when the BAP sensor has failed." 020020 Units ="in Hg" 020100 Address =0xA97C 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xFE6 000100 Cat0ID =0xB 020005 Title ="Default ECT" 020011 DescSize =0x6C 020010 Desc ="ECTFMM - Default value used for ECT when the ECT sensor has failed and (other conditions to be determined)." 020020 Units ="deg F" 020100 Address =0xA976 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x49DD 000100 Cat0ID =0xB 020005 Title ="Default Desired Idle RPM" 020011 DescSize =0x4E 020010 Desc ="FMMDSD - Default desired idle rpm when both TPS and MAF failed flags are set." 020020 Units ="rpm" 020100 Address =0xA974 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5FF5 000100 Cat0ID =0xB 020005 Title ="Default ISC Dutycycle" 020011 DescSize =0x49 020010 Desc ="FMMISC - Default ISC dutycyle when both TPS and MAF failed flags are set" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0xA972 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1790 000100 Cat0ID =0xB 020005 Title ="Default TP" 020011 DescSize =0xA6 020010 Desc ="FMCTTP - Added to closed throttle value to give a default throttle value if either the TPS has failed, is less than 'TPS Min' value or greater than 'TPS Max' value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA978 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xFE9 000100 Cat0ID =0x1 020005 Title ="Desired A/F Ratio Max" 020011 DescSize =0x59 020010 Desc ="LAMMAX - The desired A/F ratio is clipped to this limit during closed loop fuel control." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0xB0A6 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x809 000100 Cat0ID =0x1 020005 Title ="Desired A/F Ratio Min" 020011 DescSize =0x59 020010 Desc ="LAMMIN - The desired A/F ratio is clipped to this limit during closed loop fuel control." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0xB0A8 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5A85 000100 Cat0ID =0xC 020005 Title ="Desired EGR Valve Position Time Constant" 020011 DescSize =0xEF 020010 Desc ="TCDLOP - The time constant for the rolling average calculation of the 'Desired EGR Valve Position' (aka DELOPT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADC0 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x42DA 000100 Cat0ID =0x9 020005 Title ="Desired Idle RPM Self Test Time Constant" 020011 DescSize =0x18B 020010 Desc ="VTCDSN - The time constant for the rolling average calculation of the 'Desired Idle RPM' (aka DSDRPM) value during self test.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it.\r\n\r\nSetting to zero will result in the 'Desired Idle RPM Time Constant' (aka TCDESN) parameter being used in lieu of this parameter during self test." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xA366 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xBA2 000100 Cat0ID =0x6 020005 Title ="Desired Idle RPM Time Constant" 020011 DescSize =0xE5 020010 Desc ="TCDESN - The time constant for the rolling average calculation of the 'Desired Idle RPM' (aka DSDRPM) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADBE 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D8E 000100 Cat0ID =0x1 020005 Title ="Desired Rich Correction" 020011 DescSize =0x81 020010 Desc ="LMBJMP - When exiting the Filtered Idle Airmass Region this value is subtracted from the desired AF ratio to richen the mixture." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0xB0F6 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7C3D 000100 Cat0ID =0x7 020005 Title ="Disable ISC" 020011 DescSize =0xE3 020010 Desc ="Z_ISCSW - Normally this is set to \"3A\", change to \"00\" to set the ISC valve dutycycle to 0% when determining the 'Throttle Body Air Flow' (aka ITHBMA) parameter value.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020100 Address =0x5E4D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x197F 000100 Cat0ID =0x2 020005 Title ="Dwell Switch Point" 020011 DescSize =0x41 020010 Desc ="DWLTSW - Switch point for the change of maximum permitted dwell." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xAA2A 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7D4E 000100 Cat0ID =0x7 020005 Title ="Dwell Time Table Select Temperature" 020011 DescSize =0xD4 020010 Desc ="DWLTBP - The estimated coil temperature value used to determine which coil dwell time table is to be used. The tables are:\r\n\r\n'Dwell Time High Temperature' (aka FN160B)\r\n'Dwell Time Low Temperature' (aka FN160A)" 020020 Units ="deg F" 020100 Address =0xAA29 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x30FD 000100 Cat0ID =0x2 020005 Title ="Dwell Turn On Time Low RPM Clip" 020011 DescSize =0x7 020010 Desc ="MINDLA" 020020 Units ="% of PIP period" 020050 SizeInBits =0x10 020100 Address =0xAA24 020150 Flags =0x2 020200 Equation =X/655.36,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7F70 000100 Cat0ID =0x2 020005 Title ="Dwell Turn On Time High RPM Clip" 020011 DescSize =0x7 020010 Desc ="MINDLB" 020020 Units ="% of PIP period" 020050 SizeInBits =0x10 020100 Address =0xAA26 020150 Flags =0x2 020200 Equation =X/655.36,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1379 000100 Cat0ID =0x9 020005 Title ="ECT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VIECT2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA3E2 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5622 000100 Cat0ID =0x9 020005 Title ="ECT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VIECT1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA3E0 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3FEB 000100 Cat0ID =0x9 020005 Title ="ECT KOER Max" 020011 DescSize =0x7 020010 Desc ="VIECT4" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F56 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x20B8 000100 Cat0ID =0x9 020005 Title ="ECT KOER Min" 020011 DescSize =0x7 020010 Desc ="VIECT3" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F54 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DC4 000100 Cat0ID =0x4 020005 Title ="ECT Max" 020011 DescSize =0x54 020010 Desc ="ECTMAX - Value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA354 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x356A 000100 Cat0ID =0xA 020005 Title ="ECT Max at Start for Warm Up Flag" 020011 DescSize =0xC9 020010 Desc ="VECT5 - The maximum coolant temperature at start up permitted for the KAM Warm Up counter to be updated. The temperature then needs to increase beyond the 'ECT Min for Warm Up Flag' (aka VECT3) value." 020020 Units ="deg F" 020100 Address =0xA340 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x32F9 000100 Cat0ID =0x4 020005 Title ="ECT Min" 020011 DescSize =0x54 020010 Desc ="ECTMIN - Value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA352 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6FE2 000100 Cat0ID =0xA 020005 Title ="ECT Min for Warm Up Flag" 020011 DescSize =0xCB 020010 Desc ="VECT3 - The minimum coolant temperature required for the KAM Warm Up counter to be updated. The temperature at start also needs to be less than the 'ECT Max at Start for Warm Up Flag' (aka VECT5) value." 020020 Units ="deg F" 020100 Address =0xA3E6 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E9B 000100 Cat0ID =0x3 020005 Title ="ECT Time Constant" 020011 DescSize =0xD4 020010 Desc ="TCECT - The time constant for the rolling average calculation of the 'ECT' (aka ECT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADC4 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DA2 000100 Cat0ID =0x7 020005 Title ="Engine Displacement" 020011 DescSize =0xA1 020010 Desc ="SARCHG - If altered the following parameters will need adjustment too;\r\n\r\n'Manifold Fast Fill Constant' (aka FKARC1)\r\n'Manifold Slow Fill Constant' (aka FKARCH)" 020020 Units ="Cubic In." 020050 SizeInBits =0x10 020100 Address =0xA50E 020150 Flags =0x2 020200 Equation =X*0.0430981,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x568F 000100 Cat0ID =0x5 020005 Title ="Engine Warm ECT" 020011 DescSize =0x4F 020010 Desc ="TEMPFB - The minimum temperature at which the engine is considered to be warm." 020020 Units ="deg F" 020100 Address =0xB468 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2505 000100 Cat0ID =0xC 020005 Title ="EPT at Idle Back Pressure" 020011 DescSize =0x62 020010 Desc ="IDLDEL - Checked during the key on 'EPT at Idle' (aka EPTZER) update routine.\r\n\r\nTo be confirmed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xAA4C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E37 000100 Cat0ID =0xC 020005 Title ="EPT at Idle Min ECT" 020011 DescSize =0x53 020010 Desc ="CTEHI - The minimum ECT for the 'EPT at Idle' (aka EPTZER) value to be calculated." 020020 Units ="deg F" 020100 Address =0xADB4 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x34BC 000100 Cat0ID =0xC 020005 Title ="EPT at Idle RPM Hysteresis" 020011 DescSize =0x94 020010 Desc ="IERPMH - Hysteresis value added to 'Desired Idle RPM' value. If the rpm exceeds this resultant value then the 'EPT at Idle' calculation is skipped." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xADB2 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4EC4 000100 Cat0ID =0x9 020005 Title ="EPT Continuous Test Max" 020011 DescSize =0x7 020010 Desc ="VEPTIH" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x198C 000100 Cat0ID =0x9 020005 Title ="EPT Continuous Test Min" 020011 DescSize =0x7 020010 Desc ="VEPTIL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x773F 000100 Cat0ID =0x9 020005 Title ="EPT Cruise Test Min" 020011 DescSize =0x7 020010 Desc ="VEPTCL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8FA0 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4514 000100 Cat0ID =0x9 020005 Title ="EPT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VEPTHL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F94 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1B88 000100 Cat0ID =0x9 020005 Title ="EPT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VEPTLL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F92 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x592F 000100 Cat0ID =0x9 020005 Title ="EPT KOER Max" 020011 DescSize =0x7 020010 Desc ="VEPTRH" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F98 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B53 000100 Cat0ID =0x9 020005 Title ="EPT KOER Min" 020011 DescSize =0x7 020010 Desc ="VEPTRL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F96 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6A24 000100 Cat0ID =0x9 020005 Title ="EPT KOER Min Change" 020011 DescSize =0x7 020010 Desc ="VEPTDL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9E 020150 Flags =0x3 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7952 000100 Cat0ID =0x4 020005 Title ="EPT Max" 020011 DescSize =0x69 020010 Desc ="EPTMAX - Value at which the eec considers that the exhaust pressure transducer has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F90 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4FA4 000100 Cat0ID =0x4 020005 Title ="EPT Min" 020011 DescSize =0x69 020010 Desc ="EPTMIN - Value at which the eec considers that the exhaust pressure transducer has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F8E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x59C8 000100 Cat0ID =0x9 020005 Title ="EPT Test Time Constant" 020011 DescSize =0xE9 020010 Desc ="VTCEPT - The time constant for the rolling average calculation of the 'EPT' (aka EPTBAR) value during self test.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8FA4 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xF53 000100 Cat0ID =0xC 020005 Title ="EPT Time Constant" 020011 DescSize =0xF7 020010 Desc ="TCEPT - The time constant for the rolling average calculation of the 'EPT' (aka EPTBAR) and 'EPT at Idle' (aka EPTZER) values.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97F0 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E03 000100 Cat0ID =0xC 020005 Title ="EPT Transfer" 020011 DescSize =0x7 020010 Desc ="XFREPT" 020020 Units ="in H2O/counts" 020050 SizeInBits =0x10 020100 Address =0x97D4 020150 Flags =0x3 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xBA1 000100 Cat0ID =0xC 020005 Title ="EPT Transfer Reciprocol" 020011 DescSize =0x7 020010 Desc ="IXFRPR" 020020 Units ="counts/in H2O" 020050 SizeInBits =0x10 020100 Address =0x97D6 020150 Flags =0x3 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5574 000100 Cat0ID =0x12 020005 Title ="Equilibrium Fuel Transfer Constant Multiplier" 020011 DescSize =0x6B 020010 Desc ="MTEFTC - A multiplier of the result of the 'Equilibrium Fuel Transfer Constant' (aka FN1322) table lookup." 020020 Units ="multiplier" 020100 Address =0xA506 020200 Equation =X/32,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5573 000100 Cat0ID =0x12 020005 Title ="Equilibrium Intake Surface Fuel Multiplier" 020011 DescSize =0x68 020010 Desc ="MTEISF - A multiplier of the result of the 'Equilibrium Intake Surface Fuel' (aka FN1321) table lookup." 020020 Units ="multiplier" 020100 Address =0xA505 020200 Equation =X/32,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6A18 000100 Cat0ID =0x9 020005 Title ="Failure Mode Hysteresis" 020011 DescSize =0x50 020010 Desc ="FILHYS - Hysteresis value for the 'Error ** Threshold' (aka C**LVL) parameters." 020020 Units ="" 020100 Address =0xA3E7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x69F6 000100 Cat0ID =0x6 020005 Title ="FAM Deadband" 020011 DescSize =0x7 020010 Desc ="FAMLIM" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0xA548 020150 Flags =0x2 020200 Equation =X/655.36,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5E9C 000100 Cat0ID =0x6 020005 Title ="FAM Entry Airmass Maximum" 020011 DescSize =0x69 020010 Desc ="TCFAM - The maximum airmass in order for the FAM_FLG to be set.\r\n\r\nPID to be confirmed (probably wrong)" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xADCA 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x133F 000100 Cat0ID =0x6 020005 Title ="FAM Entry Max Multiplier" 020011 DescSize =0xA6 020010 Desc ="EFAMPH - On entry to the filtered air mass region the filtered air mass value is multiplied by this parameter to establish an upper clip limit on the air mass value." 020020 Units ="multiplier" 020100 Address =0xB485 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x63C9 000100 Cat0ID =0x6 020005 Title ="FAM Entry Min Multiplier" 020011 DescSize =0xA6 020010 Desc ="EFAMPL - On entry to the filtered air mass region the filtered air mass value is multiplied by this parameter to establish an lower clip limit on the air mass value." 020020 Units ="multiplier" 020100 Address =0xB486 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5673 000100 Cat0ID =0x6 020005 Title ="FAM Filter Sample Rate" 020011 DescSize =0x6B 020010 Desc ="SAMRAT - Used to pace the filter rate for the filtered airmass in terms of program background loop counts." 020020 Units ="background counts" 020100 Address =0xA536 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6399 000100 Cat0ID =0x6 020005 Title ="FAM Incremental Adder" 020011 DescSize =0x61 020010 Desc ="AMRPM - Added to desird idle rpm to give a maximum rpm below which air mass filtering can occur." 020020 Units ="rpm" 020100 Address =0xB483 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5238 000100 Cat0ID =0x6 020005 Title ="FAM Incremental Adder Hysteresis" 020011 DescSize =0x40 020010 Desc ="AMRPMH - Hysteresis for the 'FAM Incremental Adder' parameter." 020020 Units ="rpm" 020100 Address =0xB484 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x55DB 000100 Cat0ID =0x6 020005 Title ="FAM Increment/Decrement" 020011 DescSize =0x7 020010 Desc ="FAMINC" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA514 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x56DC 000100 Cat0ID =0x6 020005 Title ="FAM Maximum Clip Multiplier" 020011 DescSize =0x8A 020010 Desc ="MAXFAM - The instantaneous air mass value is multiplied by this parameter to establish an upper clip limit on the filtered airmass value." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0xA54A 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6398 000100 Cat0ID =0x6 020005 Title ="FAM Max RPM" 020011 DescSize =0x52 020010 Desc ="AMDESN - The maximum desired idle rpm at which air mass filtering can be enabled." 020020 Units ="rpm" 020100 Address =0xB482 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6366 000100 Cat0ID =0x6 020005 Title ="FAM Multiplier" 020011 DescSize =0xD4 020010 Desc ="DELTAM - A multiplier of the filtered airmass value that establishes a value that when exceeded by the instantaneous airmass causes the eec to use the instantaneous airmass in lieu of the filtered airmass value." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0xB480 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5672 000100 Cat0ID =0x6 020005 Title ="FAM TP" 020011 DescSize =0x12A 020010 Desc ="DELRAT - When the relative throttle position is less than or equal to this parameter then FAM entry is allowed providing the other conditions for FAM entry are satisfied. Set equal to the sum of the following parameters;\r\n\r\n'TPS PT Threshold' (aka DELTA)\r\n'TPS PT Threshold Hysteresis' (aka HYSTS)" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA534 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x721F 000100 Cat0ID =0x6 020005 Title ="FAM TP Hysteresis" 020011 DescSize =0x7 020010 Desc ="DLHYST" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xB488 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x49C8 000100 Cat0ID =0x5 020005 Title ="Force Continuous O/L" 020011 DescSize =0xEC 020010 Desc ="Z_OLSW - Normally this is set to \"D7\", change to \"20\" to prevent the ecu going into closed loop mode.\r\n\r\nWARNING: Do not enter any value other than one of these.\r\n\r\nThis needs verifying that CL is forced under all operating conditions." 020020 Units ="n/a" 020100 Address =0x4274 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6244 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Cold Start Delay #1" 020011 DescSize =0x129 020010 Desc ="NITMR1 - When the ECT at start is less than the 'Cold Start Max ECT' value this is the minimum time that must pass since exiting crank in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Cold Start Delay #2' value also needs exceeding." 020020 Units ="secs" 020100 Address =0xB0C4 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B7C 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Cold Start Delay #2" 020011 DescSize =0x147 020010 Desc ="NITMR4 - When the ECTat start is less than the 'Cold Start Max ECT' value this is the minimum time that must pass since the ECT exceeded the 'Engine Warm ECT' value in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Cold Start Delay #1' value also needs exceeding." 020020 Units ="secs" 020100 Address =0xB0C5 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A8B 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Hot Start Delay" 020011 DescSize =0xD6 020010 Desc ="NITMR3 - When the ECT at start is greater than the 'Hot Start Min ECT' value this is the minimum time that must pass since exiting crank in order for it to be possible to use fixed injector timing when in neutral." 020020 Units ="secs" 020100 Address =0xB0C1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xE01 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Warm Start Delay #1" 020011 DescSize =0x140 020010 Desc ="NITMR2 - When the ECT at start is between the 'Cold Start Max ECT' and 'Hot Start Min ECT' values this is the minimum time that must pass since exiting crank in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Warm Start Delay #2' value also needs exceeding." 020020 Units ="secs" 020100 Address =0xB0C2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x706D 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Warm Start Delay #2" 020011 DescSize =0x15F 020010 Desc ="NITMR5 - When the ECT at start is between the 'Cold Start Max ECT' and 'Hot Start Min ECT' values this is the minimum time that must pass since the ECT exceeded the 'Engine Warm ECT' value in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Warm Start Delay #1' value also needs exceeding." 020020 Units ="secs" 020100 Address =0xB0C3 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x58D6 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Max ECT" 020011 DescSize =0x5 020010 Desc ="LDEH" 020020 Units ="deg F" 020100 Address =0xAD89 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7778 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Min ECT" 020011 DescSize =0x5 020010 Desc ="LDEL" 020020 Units ="deg F" 020100 Address =0xAD88 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5348 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Min Load%" 020011 DescSize =0xFF 020010 Desc ="LDMH - When LOAD% is greater or equal to the sum of this value plus the 'Fuel Lugging Mode O/L Min Load% Hysteresis' (aka LDMHH) parameter value then one of the conditions required for the setting of the 'Lugging O/L Flag' (aka LDFLG) will have been met." 020020 Units ="load%" 020050 SizeInBits =0x10 020100 Address =0xAD8C 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x83A 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Min Load% Hysteresis" 020011 DescSize =0x59 020010 Desc ="LDMHH - Hysteresis value for the 'Fuel Lugging Mode O/L Min Load%' (aka LDMH) parameter." 020020 Units ="load%" 020050 SizeInBits =0x10 020100 Address =0xAD8E 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x392C 000100 Cat0ID =0x1 020005 Title ="Fuel Global Multiplier" 020011 DescSize =0xAB 020010 Desc ="OLMCL - A global multiplier that adjusts the desired A/F ratio when in open loop mode. \r\n\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0xAD90 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x64D9 000100 Cat0ID =0x9 020005 Title ="Fuel Pump Monitor KOEO Test Delay" 020011 DescSize =0x9 020010 Desc ="V_FPMDLY" 020020 Units ="secs" 020100 Address =0xA348 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x504D 000100 Cat0ID =0x9 020005 Title ="Fuel Pump Monitor Test Delay" 020011 DescSize =0x8 020010 Desc ="V_FPMTM" 020020 Units ="secs" 020100 Address =0xA349 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x291E 000100 Cat0ID =0x9 020005 Title ="Fuel Pump Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT7 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA414 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3A22 000100 Cat0ID =0x9 020005 Title ="Fuel Test Exit Delay" 020011 DescSize =0x9 020010 Desc ="VDLY8 - " 020020 Units ="secs" 020100 Address =0xA32E 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3A12 000100 Cat0ID =0x9 020005 Title ="Goose Idle Delay Time" 020011 DescSize =0x7 020010 Desc ="VISDL3" 020020 Units ="secs" 020100 Address =0xB49A 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7FA1 000100 Cat0ID =0x9 020005 Title ="Goose Idle RPM" 020011 DescSize =0x7 020010 Desc ="ISLBND" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB49C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x3DD 000100 Cat0ID =0x9 020005 Title ="Goose Minimum MAP Change" 020011 DescSize =0x4D 020010 Desc ="V_GOOSMP -The minimum MAP change to determine goose test has been undetaken." 020020 Units ="in Hg" 020100 Address =0xA35B 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x749 000100 Cat0ID =0x9 020005 Title ="Goose Minimum RPM Change" 020011 DescSize =0x4C 020010 Desc ="V_GOOSN -The minimum rpm change to determine goose test has been undetaken." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA35C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x472F 000100 Cat0ID =0x9 020005 Title ="Goose Minimum TP Change" 020011 DescSize =0x53 020010 Desc ="V_GOOSTP - The minimum throttle change to determine goose test has been undetaken." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA360 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x236A 000100 Cat0ID =0x9 020005 Title ="Goose Spark" 020011 DescSize =0x9 020010 Desc ="V_GOOSPK" 020020 Units ="degrees" 020050 SizeInBits =0x10 020100 Address =0xA35E 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xB1F 000100 Cat0ID =0x9 020005 Title ="Goose Test Desired RPM" 020011 DescSize =0x9 020010 Desc ="NGOOSE -" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB49E 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x68F1 000100 Cat0ID =0x9 020005 Title ="Goose Test Time" 020011 DescSize =0x75 020010 Desc ="V_GOOSEC - The maximum time allowed for the the operator to respond to the request for the throttle to be 'goosed'." 020020 Units ="secs" 020100 Address =0xA35A 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1EF0 000100 Cat0ID =0x9 020005 Title ="HEGO Average Test Time Constant" 020011 DescSize =0xF2 020010 Desc ="VTCEGO - The time constant for the rolling average calculation of the 'HEGO Average' (aka EGOBAR) value during self test.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xA358 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E39 000100 Cat0ID =0x5 020005 Title ="HEGO Min Switches Before Warm" 020011 DescSize =0x99 020010 Desc ="EGOCL1 - The number of HEGO switches required for the WARM_EGO_FLAG to be set providing the appropriate 'Warm HEGO Flag ....' delay times have been met." 020020 Units ="no." 020100 Address =0xB09C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x583E 000100 Cat0ID =0xB 020005 Title ="HEGO Switch Time Delay" 020011 DescSize =0x8A 020010 Desc ="BYPLES - When the time since the last HEGO switch occurred exceeds this value then the 'Lack of HEGO Switching Flag' (aka LEGOFG) is set." 020020 Units ="secs" 020100 Address =0xA932 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4467 000100 Cat0ID =0x9 020005 Title ="HEGO Test Lean Time Wait" 020011 DescSize =0x7 020010 Desc ="VIPTM3" 020020 Units ="secs" 020100 Address =0xB492 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x457B 000100 Cat0ID =0x9 020005 Title ="HEGO Test Min RPM" 020011 DescSize =0x6 020010 Desc ="VNMIN" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA32C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xF6F 000100 Cat0ID =0x9 020005 Title ="HEGO Test Min Time at C/L ECT" 020011 DescSize =0x92 020010 Desc ="VEGOTM - The minimum time after the minimum coolant temperature for closed loop operation has been reached before the HEGO test can be performed." 020020 Units ="secs" 020100 Address =0xA37C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x651F 000100 Cat0ID =0x9 020005 Title ="HEGO Test Rich Time Wait" 020011 DescSize =0x7 020010 Desc ="VIPTM4" 020020 Units ="secs" 020100 Address =0xA97D 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7EAA 000100 Cat0ID =0x9 020005 Title ="HEGO Test Switch Time Delay" 020011 DescSize =0x7 020010 Desc ="VIPTM2" 020020 Units ="secs" 020100 Address =0xA440 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x47DC 000100 Cat0ID =0x7 020005 Title ="High Speed Fan High Load Max MPH" 020011 DescSize =0x59 020010 Desc ="HSFVS - The maximum mph for the 'High Speed Fan High Load On Temp' parameter to be used." 020020 Units ="mph" 020100 Address =0xA96F 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1F86 000100 Cat0ID =0x7 020005 Title ="High Speed Fan High Load Min Load" 020011 DescSize =0x5B 020010 Desc ="HSFLOD - The minimum load for the 'High Speed Fan High Load On Temp' parameter to be used." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xA970 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7E86 000100 Cat0ID =0x7 020005 Title ="High Speed Fan High Load Min RPM" 020011 DescSize =0x5A 020010 Desc ="HSFRPM - The minimum rpm for the 'High Speed Fan High Load On Temp' parameter to be used." 020020 Units ="rpm" 020100 Address =0xA96E 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5F9A 000100 Cat0ID =0x7 020005 Title ="High Speed Fan High Load On Temp" 020011 DescSize =0x172 020010 Desc ="HSFEC1 - A lower coolant temperature than which the high speed fan normally turns on, used when minimum rpm, load and maximum mph criteria are met. Typically set 12 deg F higher than the 'Low Speed Fan On Temp' parameter. The associated conditional parameters are:\r\n\r\nHigh Speed Fan High Load Max MPH\r\nHigh Speed Fan High Load Min Load\r\nHigh Speed Fan High Load Min RPM" 020020 Units ="deg F" 020100 Address =0xA96C 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5855 000100 Cat0ID =0x9 020005 Title ="High Speed Fan Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT3 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA40E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5731 000100 Cat0ID =0x9 020005 Title ="High Speed Fan Open Circuit Check Time" 020011 DescSize =0x7 020010 Desc ="VDLHED" 020020 Units ="secs" 020100 Address =0xA396 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3071 000100 Cat0ID =0x7 020005 Title ="High Speed Fan Normal On Temp" 020011 DescSize =0xA2 020010 Desc ="HSFEC2 - The coolant temperature at which the high speed fan normally turns on. Typically set 8 deg F higher than 'High Speed Fan High Load On Temp' temperature." 020020 Units ="deg F" 020100 Address =0xA96D 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x874 000100 Cat0ID =0x7 020005 Title ="High Speed Fan Temperature Hysteresis" 020011 DescSize =0x27 020010 Desc ="HSFHYS - Typically set to 4 degrees F." 020020 Units ="deg F" 020100 Address =0xA963 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xCCF 000100 Cat0ID =0x9 020005 Title ="High Speed Fan Test Throttle Depress Time" 020011 DescSize =0x60 020010 Desc ="VHFNTM - The minimum time to hold the throttle open for to enable the KOEO high speed fan test." 020020 Units ="secs" 020100 Address =0xA39F 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7229 000100 Cat0ID =0x5 020005 Title ="Hot Start Min ECT" 020011 DescSize =0xC2 020010 Desc ="CTHIGH - The minimum ECT for a hot start condition to be recognised.\r\n\r\nThis is also the minimum ECT in order for the 'CT Neutral Timer' (aka CTNTMR) to count up (other conditions permitting). " 020020 Units ="deg F" 020100 Address =0xB466 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x570B 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Decrement for A/C" 020011 DescSize =0x6F 020010 Desc ="DACPPM - The reduction in predicted idle airflow through the ISC valve required when the aircon is turned off." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA552 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x570A 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Increment for A/C" 020011 DescSize =0x6C 020010 Desc ="ACPPM - The increase in predicted idle airflow through the ISC valve required when the aircon is turned on." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA550 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5774 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Increment for Heated Windcreen" 020011 DescSize =0x77 020010 Desc ="HWPPM - The increase in predicted idle airflow through the ISC valve required when the heated windscreen is turned on." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA908 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x570C 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Increment for Power Steering" 020011 DescSize =0x8A 020010 Desc ="PSPPM - The increase in predicted idle airflow through the ISC valve required when the power steering places addition load on the engine." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA554 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x693D 000100 Cat0ID =0x6 020005 Title ="Idle GPAS Clip Limit" 020011 DescSize =0x5A 020010 Desc ="ISCLPD - If the base target idle speed values have been altered then adjust this to suit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA546 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x43E5 000100 Cat0ID =0x6 020005 Title ="Idle GPAS Minimum Time" 020011 DescSize =0x80 020010 Desc ="CRKTIM - The minimum time in run mode that must be exceeded in order for the 'Idle GPAS Clip Limit' (aka ISCLPD) to be invoked." 020020 Units ="secs" 020100 Address =0xAD9C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x62ED 000100 Cat0ID =0x6 020005 Title ="Idle RPM Adder for A/C" 020011 DescSize =0x89 020010 Desc ="DNAC - Adds rpm to 'Desired Idle RPM' when aircon clutch is engaged, used to compensate for the additional load the compressor imposes." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA544 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x890 000100 Cat0ID =0x6 020005 Title ="Idle RPM Adder for A/C Time" 020011 DescSize =0x54 020010 Desc ="DACTM - Time to maintain idle aircon rpm adder after aircon clutch has disengaged." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xA556 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x51A2 000100 Cat0ID =0x6 020005 Title ="Idle RPM Adder for Power Steering" 020011 DescSize =0x82 020010 Desc ="DNPOWS - Adds rpm to 'Desired Idle RPM' when power steering is engaged, used to compensate for the additional load this imposes." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA558 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x40BB 000100 Cat0ID =0x6 020005 Title ="Idle RPM for Heated Windscreen" 020011 DescSize =0x59 020010 Desc ="HWRPM - Minimum idle rpm in neutral when the heated windscreen is on for the first time." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8C04 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2D91 000100 Cat0ID =0x6 020005 Title ="Idle Speed Drive" 020011 DescSize =0xE6 020010 Desc ="DRBASE - Base target idle speed in drive before adders. If altered, adjust the 'Max RPM for Idle Flag' (aka IDLRPM) parameter too. The 'ISC Gain vs RPM Error' (aka FN824) parameter might also need adjusting too (to be confirmed)." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA540 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5583 000100 Cat0ID =0x6 020005 Title ="Idle Speed Neutral" 020011 DescSize =0xE8 020010 Desc ="NUBASE - Base target idle speed in neutral before adders. If altered, adjust the 'Max RPM for Idle Flag' (aka IDLRPM) parameter too. The 'ISC Gain vs RPM Error' (aka FN824) parameter might also need adjusting too (to be confirmed)." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA53E 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x22BB 000100 Cat0ID =0x6 020005 Title ="Idle Startup Adder Time" 020011 DescSize =0x6E 020010 Desc ="TKDTM - Time since exiting crank when 'ISC Startup Adder' (aka FN826A) is used as a 'Desired Idle RPM' adder." 020020 Units ="secs" 020100 Address =0xA55A 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5CD6 000100 Cat0ID =0x9 020005 Title ="IDM Error Threshold" 020011 DescSize =0xA 020010 Desc ="IDMLVL - " 020020 Units ="" 020100 Address =0x8F30 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1119 000100 Cat0ID =0x9 020005 Title ="IDM Error Upcount" 020011 DescSize =0x9 020010 Desc ="IDMUP - " 020020 Units ="" 020100 Address =0x8F46 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x529 000100 Cat0ID =0x7 020005 Title ="Ignition Degrees Per PIP" 020011 DescSize =0x6B 020010 Desc ="DEGPIP - The number of crank degrees per PIP interval. 90 = 8 cylinder, 120 = 6 cylinder, 180 = 4 cylinder" 020020 Units ="degrees" 020050 SizeInBits =0x10 020100 Address =0xB0AE 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x63CB 000100 Cat0ID =0x1 020005 Title ="Initial FAM" 020011 DescSize =0x5 020010 Desc ="IFAM" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xB48A 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x4661 000100 Cat0ID =0xB 020005 Title ="Initial TP" 020011 DescSize =0x8A 020010 Desc ="RATIV - Closed throttle value used by the eec if either the TPS has failed, is less than 'TPS Max' value or greater than 'TPS Max' value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8C02 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x46A1 000100 Cat0ID =0x7 020005 Title ="Injector Fire Method" 020011 DescSize =0x2A 020010 Desc ="OUTINJ - 1 = sequential, 2 = simultaneous" 020020 Units ="n/a" 020100 Address =0xB0B5 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x78E7 000100 Cat0ID =0x7 020005 Title ="Injector High Slope" 020011 DescSize =0x1CA 020010 Desc ="AHISL - The injector primary fuel slope, used in conjunction with the 'Injector Low Slope' (aka ALOSL) to calculate injection pulsewidths greater than those using the low slope alone. Set to the mass flow rate of an individual fuel injector. When altered, the following parameters will need adjusting too;\r\n\r\n'Injector Low Slope' (aka ALOSL)\r\n'Injector Breakpoint' (aka FN389)\r\n'Injector Offset vs Voltage' (aka FN367)\r\n'Cranking Fuel PW vs ECT' (aka FN348)" 020020 Units ="lb/hr" 020050 SizeInBits =0x10 020100 Address =0xA512 020150 Flags =0x2 020200 Equation =X/582.535278,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6047 000100 Cat0ID =0x7 020005 Title ="Injector Low Slope" 020011 DescSize =0x338 020010 Desc ="ALOSL - Used to calculate the injection pulsewidth during cranking and short pulsewidths. Set to a value larger than actual injector size to compensate for non linear opening at short durations. Typically 1.33 * 'Injector High Slope' (aka AHISL) for 19 lb/hr injectors reducing to 1.08 * 'Injector High Slope' (aka AHISL) for 83 lb/hr injectors. When altered, the following parameters will need adjusting too;\r\n\r\n'Injector Breakpoint' (aka FN389)\r\n'Injector Offset vs Voltage' (aka FN367)\r\n'Cranking Fuel PW vs ECT' (aka FN3\r\n\r\nAn alternative is to set this parameter to the same value as the 'Injector High Slope' (aka AHISL) in which case the 'Injector Breakpoint' (aka FN389) parameter is not used. The 'Injector Offset vs Voltage' (aka FN367) is critical in getting accurate fuel pulsewidths with this method of tuning." 020020 Units ="lb/hr" 020050 SizeInBits =0x10 020100 Address =0xA510 020150 Flags =0x2 020200 Equation =X/582.535278,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6E2F 000100 Cat0ID =0x1 020005 Title ="Injector Timing Delay" 020011 DescSize =0xB5 020010 Desc ="IDKADD - Injector timing delay added to the result of the 'Injector Timing' (aka FN1315) lookup following multiplication by the 'Injector Timing Multiplier (aka IDKMUL) parameter. " 020020 Units ="crank deg" 020050 SizeInBits =0x10 020100 Address =0xA4F2 020150 Flags =0x2 020200 Equation =X/16,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6D7B 000100 Cat0ID =0x1 020005 Title ="Injector Timing Multiplier" 020011 DescSize =0x58 020010 Desc ="IDKMUL - A multiplier of the result of the 'Injector Timing' (aka FN1315) table lookup." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0xA4F0 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x591E 000100 Cat0ID =0x7 020005 Title ="Injector Timing Time Constant" 020011 DescSize =0xE3 020010 Desc ="TCINJD - The time constant for the rolling average calculation of the 'Injector Delay' (aka INJDLY) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADD8 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29FD 000100 Cat0ID =0x7 020005 Title ="Injector Timing Value at Idle" 020011 DescSize =0x7C 020010 Desc ="MIDTV - Injector timing value used when in drive and the 'Enable Special Injector Timing at Idle' (aka CIDRSW) flag is set." 020020 Units ="crank deg" 020100 Address =0xB0BF 020200 Equation =X*4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x389B 000100 Cat0ID =0x7 020005 Title ="Injector Timing Value for MFA" 020011 DescSize =0x105 020010 Desc ="MINTV - The injector timing value used when in fuel economy mode, it overrides all other injector timing parameters. Can indicate the start or end timing point of the injector pulse depending on the setting of the 'Injector Timing Edge' (aka INJREF) parameter." 020020 Units ="crank deg" 020100 Address =0xB0BE 020200 Equation =X*4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x25F 000100 Cat0ID =0x7 020005 Title ="Injector Timing Value in Neutral" 020011 DescSize =0xC0 020010 Desc ="CINTV - Injector timing value used when the 'Enable Special Injector Timing in Neutral' (aka CINTSW) flag is set providing the startup delay for fixed injector timing conditions have expired." 020020 Units ="crank deg" 020100 Address =0xA4D3 020200 Equation =X*4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x501F 000100 Cat0ID =0x7 020005 Title ="Injectors Per Output Port" 020011 DescSize =0x3C 020010 Desc ="INJOUT - The number of injectors fired by each output port." 020020 Units ="no." 020100 Address =0xB0B3 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1478 000100 Cat0ID =0x7 020005 Title ="Intake Air Control Valve Open RPM" 020011 DescSize =0x7B 020010 Desc ="NIAC - RPM at which the intake manifold air control valve is opened. Requires 'Auxillary Hardware Present' to be set to 3." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA314 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2EFD 000100 Cat0ID =0x7 020005 Title ="Intake Air Control Valve Open RPM Hysteresis" 020011 DescSize =0x7D 020010 Desc ="NIACH - Subtracted from 'Intake Air Control Valve Open RPM' to establish rpm at which valve closes. Typically set at 500rpm." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA316 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5709 000100 Cat0ID =0x6 020005 Title ="ISC Air Drive To Neutral" 020011 DescSize =0x6 020010 Desc ="DNPPM" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA54E 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5708 000100 Cat0ID =0x6 020005 Title ="ISC Air Neutral To Drive" 020011 DescSize =0x6 020010 Desc ="NDPPM" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA54C 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x560B 000100 Cat0ID =0x6 020005 Title ="ISC C/L RPM Correction Airmass Max" 020011 DescSize =0x5B 020010 Desc ="PSIBRM - The maximum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA51E 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x560C 000100 Cat0ID =0x6 020005 Title ="ISC C/L RPM Correction Airmass Min" 020011 DescSize =0x5B 020010 Desc ="PSIBRN - The minimum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA520 020150 Flags =0x3 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x127 000100 Cat0ID =0x9 020005 Title ="ISC C/L RPM Correction Airmass Test Max**" 020011 DescSize =0x6C 020010 Desc ="VSIBRM - The maximum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted during self test." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xB40A 020150 Flags =0x3 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29E4 000100 Cat0ID =0x9 020005 Title ="ISC C/L RPM Correction Test Rate" 020011 DescSize =0x66 020010 Desc ="V860 - Substitution value used instead of 'ISC C/L RPM Correction Rate' value when in self test mode." 020020 Units ="rate" 020050 SizeInBits =0x10 020100 Address =0xB4A8 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1BFE 000100 Cat0ID =0x9 020005 Title ="ISC C/L RPM Correction Airmass Test Min" 020011 DescSize =0x6C 020010 Desc ="VSIBRN - The minimum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted during self test." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xB4A2 020150 Flags =0x3 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x58D8 000100 Cat0ID =0x9 020005 Title ="ISC High RPM Test Delay Time" 020011 DescSize =0x7 020010 Desc ="VISDL1" 020020 Units ="secs" 020100 Address =0xB494 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x787C 000100 Cat0ID =0x9 020005 Title ="ISC High RPM Test RPM" 020011 DescSize =0x7 020010 Desc ="ISUBND" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB498 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x563D 000100 Cat0ID =0x6 020005 Title ="ISC Gain Associated With The Desired DASPOT Airflow" 020011 DescSize =0x7 020010 Desc ="DASPTK" 020020 Units ="lb/min per TP count" 020050 SizeInBits =0x10 020100 Address =0xA526 020150 Flags =0x2 020200 Equation =X/1048576,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x62AD 000100 Cat0ID =0x6 020005 Title ="ISC Gain For Overspeed in Drive" 020011 DescSize =0x7E 020010 Desc ="KPSIDD - Multiplied by engine speed error and the 'ISC Gain vs RPM Error' lookup result, used as input in IPSIBR calculation." 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0xA51C 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x69C2 000100 Cat0ID =0x6 020005 Title ="ISC Gain For Overspeed in Neutral" 020011 DescSize =0x7E 020010 Desc ="KPSIND - Multiplied by engine speed error and the 'ISC Gain vs RPM Error' lookup result, used as input in IPSIBR calculation." 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0xA518 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x551B 000100 Cat0ID =0x9 020005 Title ="ISC Gain For Overspeed in Self Test" 020011 DescSize =0x51 020010 Desc ="VPSIND - Multiplied by engine speed error, used as input in IPSIBR calculation. " 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0xB4A4 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x7619 000100 Cat0ID =0x6 020005 Title ="ISC Gain For Underspeed in Drive" 020011 DescSize =0x7E 020010 Desc ="KPSIDU - Multiplied by engine speed error and the 'ISC Gain vs RPM Error' lookup result, used as input in IPSIBR calculation." 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0xA51A 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5516 000100 Cat0ID =0x6 020005 Title ="ISC Gain For Underspeed in Neutral" 020011 DescSize =0x7E 020010 Desc ="KPSINU - Multiplied by engine speed error and the 'ISC Gain vs RPM Error' lookup result, used as input in IPSIBR calculation." 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0xA516 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x1AA0 000100 Cat0ID =0x9 020005 Title ="ISC Gain For Underspeed in Self Test" 020011 DescSize =0x51 020010 Desc ="VPSINU - Multiplied by engine speed error, used as input in IPSIBR calculation. " 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0xB4A6 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x56A4 000100 Cat0ID =0xA 020005 Title ="ISC KAM Update Rate" 020011 DescSize =0x7 020010 Desc ="UPDATM" 020020 Units ="clock ticks" 020100 Address =0xA53B 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x560E 000100 Cat0ID =0x6 020005 Title ="ISC Min Airflow" 020011 DescSize =0x7 020010 Desc ="DEBYCP" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA524 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5640 000100 Cat0ID =0x6 020005 Title ="ISC RPM Control Deadband" 020011 DescSize =0x1C7 020010 Desc ="RPMCTL - This parameter is used by two different sections of the idle control software.\r\n\r\na) If the rpm is less than the desired idle rpm plus this parameter then ISC closed loop rpm control is allowed providing the other conditions for rpm control are satisfied.\r\n\r\nb) If the rpm is less than the desired idle rpm minus this parameter when the ISC dutycycle is greater than 98% then part of the idle routine is skipped (actual routine to be determined)" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA52C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5642 000100 Cat0ID =0x6 020005 Title ="ISC RPM Control Min Speed" 020011 DescSize =0xA4 020010 Desc ="MINMPH - If the vehicle speed is less than this parameter then ISC closed loop rpm control is allowed providing the other conditions for rpm control are satisfied." 020020 Units ="mph" 020100 Address =0xA530 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5671 000100 Cat0ID =0x6 020005 Title ="ISC RPM Deadband" 020011 DescSize =0x7 020010 Desc ="RPMDED" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA532 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x56A3 000100 Cat0ID =0x6 020005 Title ="ISC RPM Deadband Time" 020011 DescSize =0x8F 020010 Desc ="UPDISC - The minimum time the rpm must be at the desired idle rpm ( + or - the 'ISC RPM Deadband' value) in order for ISC KAM update to occur." 020020 Units ="secs" 020100 Address =0xA53A 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5641 000100 Cat0ID =0x6 020005 Title ="ISC RPM Deviation Allowed" 020011 DescSize =0xD3 020010 Desc ="NDIF - The maximum change in rpm over the time period specified by the 'ISC RPM Deviation Time' (aka ISCTM).\r\n\r\nToo small a value will prevent closed loop idle control. Too large a value will negate any effect." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA52E 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5674 000100 Cat0ID =0x6 020005 Title ="ISC RPM Deviation RPM" 020011 DescSize =0x6 020010 Desc ="ISCTM" 020020 Units ="secs" 020100 Address =0xA537 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7C26 000100 Cat0ID =0x9 020005 Title ="ISC Self Test Dutycycle Multiplier" 020011 DescSize =0x73 020010 Desc ="V820A - Replacement value for 'ISC Dutycycle Multiplier vs Load' (aka FN820B) lookup result used during self test." 020020 Units ="multiplier" 020100 Address =0xB4AA 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x540C 000100 Cat0ID =0x5 020005 Title ="Key On Update Flag Reset Delay" 020011 DescSize =0x73 020010 Desc ="TKYON4 - If the 'Time Since Start' is greater than this value then the 'Key On Update Flag' (aka BPKFLG) is reset." 020020 Units ="secs" 020100 Address =0xAA54 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7A67 000100 Cat0ID =0x5 020005 Title ="Key On Update Max Time" 020011 DescSize =0x7 020010 Desc ="TKYON3" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xAA52 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x501 000100 Cat0ID =0x5 020005 Title ="Key On Update Min Time" 020011 DescSize =0x7 020010 Desc ="TKYON2" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xAA50 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x263D 000100 Cat0ID =0x5 020005 Title ="Keypower Scaling Factor" 020011 DescSize =0x3D 020010 Desc ="KSF - Used in the instantaneous battery voltage calculation." 020020 Units ="muliplier" 020050 SizeInBits =0x10 020100 Address =0xB47C 020150 Flags =0x2 020200 Equation =X/8192,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x5BD1 000100 Cat0ID =0x2 020005 Title ="Knock Advance Limit" 020011 DescSize =0x56 020010 Desc ="ADVLIM - The amount of spark advance above 'Spark Advance Final' (aka SAF) permitted." 020020 Units ="deg adv" 020100 Address =0xAA2F 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7DDF 000100 Cat0ID =0x2 020005 Title ="Knock Cylinder Strategy" 020011 DescSize =0x1C2 020010 Desc ="KNKCYL - Determines whether an individual or multi cylinder knock strategy is to be used.\r\n\r\nSet to '1' to for a multi cylinder knock strategy. This will result in all cylinders being retarded by the same amount when spark retard for knock is applied.\r\n\r\nSet equal to the number of cylinders for an individual cylinder knock strategy. This will result in each cylinder being retarded by the a different amount when spark retard for knock is applied." 020020 Units ="" 020100 Address =0xAA46 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4710 000100 Cat0ID =0x2 020005 Title ="Knock Maximum Retard" 020011 DescSize =0x3C 020010 Desc ="RETLIM - The maximum spark retard pulled when knock occurs." 020020 Units ="deg adv" 020100 Address =0xAA2E 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x511 000100 Cat0ID =0x2 020005 Title ="Knock Min ECT" 020011 DescSize =0x3F 020010 Desc ="ECTNOK - The minimum ECT for the knock strategy to be enabled." 020020 Units ="deg F" 020100 Address =0xAA3A 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x747A 000100 Cat0ID =0x2 020005 Title ="Knock Min Load" 020011 DescSize =0x40 020010 Desc ="LODNOK - The minimum Load for the knock strategy to be enabled." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xAA38 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5C06 000100 Cat0ID =0x2 020005 Title ="Knock Min RPM" 020011 DescSize =0x3F 020010 Desc ="RPMMIN - The minimum rpm for the knock strategy to be enabled." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xAA36 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7281 000100 Cat0ID =0x9 020005 Title ="Knock Threshold Pulse Time" 020011 DescSize =0x6 020010 Desc ="V_KTS" 020020 Units ="clock ticks" 020100 Address =0xA363 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5C3B 000100 Cat0ID =0x2 020005 Title ="Knock Threshold Window Position Delay" 020011 DescSize =0xB2 020010 Desc ="WOPEN - The minimum delay after the rising edge of the PIP before the KTS pulse will be output. Added to the result of the 'Knock Threshold Window Position' (aka FN145A) lookup." 020020 Units ="PIP period fraction" 020050 SizeInBits =0x10 020100 Address =0xAA3E 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5C3C 000100 Cat0ID =0x2 020005 Title ="Knock Threshold Window Time Min" 020011 DescSize =0x2D 020010 Desc ="WINLEN - The minimum width of the KTS pulse." 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0xAA40 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5C6D 000100 Cat0ID =0x2 020005 Title ="Knock Window Closed Time" 020011 DescSize =0x3C 020010 Desc ="WINCLD - The number of PIPs the knock window is closed for." 020020 Units ="no." 020100 Address =0xAA47 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5C6A 000100 Cat0ID =0x2 020005 Title ="Knock Window Maximum RPM" 020011 DescSize =0x39 020010 Desc ="RPMCNL - The rpm above which the knock window is closed." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xAA42 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7B38 000100 Cat0ID =0x1 020005 Title ="Load Min for C/L" 020011 DescSize =0x6 020010 Desc ="LOLOD" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xB09E 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7FF3 000100 Cat0ID =0x1 020005 Title ="Load Min for C/L Hysteresis" 020011 DescSize =0x7 020010 Desc ="LOLODH" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xB0A0 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5676 000100 Cat0ID =0x1 020005 Title ="Load% Min for O/L Hysteresis" 020011 DescSize =0xC6 020010 Desc ="HLODH - Defines the amount LOAD% needs to be below the 'Load% Min for O/L vs ECT' (aka FN320A) table lookup result in order for the 'Inhibit High Load Timer Flag' to be cleared once it's been set." 020020 Units ="load%" 020050 SizeInBits =0x10 020100 Address =0xB0A2 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5372 000100 Cat0ID =0x5 020005 Title ="Low Battery Voltage" 020011 DescSize =0x5E 020010 Desc ="LOWBAT - Voltage the eec considers too low for accurate operation of some sensors/actuators. " 020020 Units ="volts" 020100 Address =0xA31B 020200 Equation =X/16,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5675 000100 Cat0ID =0x6 020005 Title ="Low Load" 020011 DescSize =0x9C 020010 Desc ="LOWLOD - Used in \"ISC Mode Flag\" selection. If set to zero, along with the \"A/C Low Load Adder\", the \"ISC Mode Flag\" is always set to 2 (rpm lockout mode)." 020020 Units ="load" 020100 Address =0xA538 020200 Equation =X*64/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7BD3 000100 Cat0ID =0x7 020005 Title ="Low Speed Fan Min Time Before High Speed" 020011 DescSize =0x67 020010 Desc ="EDFTM - The minimum delay before turning on the high speed fan after the turning on the low speed fan." 020020 Units ="secs" 020100 Address =0xA967 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x407F 000100 Cat0ID =0x7 020005 Title ="Low Speed Fan On Temp" 020011 DescSize =0x46 020010 Desc ="LSFECT - The coolant temperature at which the low speed fan turns on." 020020 Units ="deg F" 020100 Address =0xA962 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5D8D 000100 Cat0ID =0x7 020005 Title ="Low Speed Fan On Temp Hysteresis" 020011 DescSize =0x27 020010 Desc ="LSFHYS - Typically set to 4 degrees F." 020020 Units ="deg F" 020100 Address =0xA964 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3689 000100 Cat0ID =0x9 020005 Title ="Low Speed Fan Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT8 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA416 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3D0B 000100 Cat0ID =0x9 020005 Title ="Low Speed Fan Open Circuit Check Time" 020011 DescSize =0x7 020010 Desc ="VDLEDF" 020020 Units ="secs" 020100 Address =0xA395 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x46A2 000100 Cat0ID =0x9 020005 Title ="Low Speed Fan Test Throttle Depress Time" 020011 DescSize =0x5F 020010 Desc ="VLFNTM - The minimum time to hold the throttle open for to enable the KOEO low speed fan test." 020020 Units ="secs" 020100 Address =0xA39E 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5378 000100 Cat0ID =0xB 020005 Title ="MAF Failure Flag Counter Hysteresis" 020011 DescSize =0x7 020010 Desc ="MFMHYS" 020020 Units ="counts" 020100 Address =0xA320 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x24C8 000100 Cat0ID =0x9 020005 Title ="MAF KOEO Min" 020011 DescSize =0x7 020010 Desc ="VMAFO1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA3F0 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3BD9 000100 Cat0ID =0x9 020005 Title ="MAF KOER Max" 020011 DescSize =0x7 020010 Desc ="VMAFR2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA3F4 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x531C 000100 Cat0ID =0x9 020005 Title ="MAF KOER Min" 020011 DescSize =0x7 020010 Desc ="VMAFR1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA3F2 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x100D 000100 Cat0ID =0x4 020005 Title ="MAF Max RPM for Max Volts Test" 020011 DescSize =0x7B 020010 Desc ="VMARPM - If the rpm is greater than this value then the MAF voltage is not checked against the 'MAF Max Volts' parameter." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA3FA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6456 000100 Cat0ID =0x4 000101 Cat1ID =0x9 020005 Title ="MAF Max Volts" 020011 DescSize =0x5D 020010 Desc ="VMAMAX - Limit indicating short circuit that is checked during normal running and KOEO test." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA3F6 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6365 000100 Cat0ID =0x3 020005 Title ="MAF Min Airmass Clip" 020011 DescSize =0x6 020010 Desc ="MINAM" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xB47E 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x53 000100 Cat0ID =0x4 020005 Title ="MAF Min Volts" 020011 DescSize =0x4E 020010 Desc ="VMAMIN - Limit indicating open circuit that is checked during normal running." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA3F8 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x30A 000100 Cat0ID =0x9 020005 Title ="MAF PIP Limit" 020011 DescSize =0xB 020010 Desc ="VMAFPIPLMT" 020020 Units ="mSecs" 020050 SizeInBits =0x10 020100 Address =0xA3EE 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5FE2 000100 Cat0ID =0x7 020005 Title ="Manifold Air Charge Fraction" 020011 DescSize =0x94 020010 Desc ="FILFRC - Ratio of instantaneous air charge / filtered air charge used to determine whether the slow or fast manifold filter constant is to be used." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0xA902 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1378 000100 Cat0ID =0x12 020005 Title ="Manifold Fast Fill Constant" 020011 DescSize =0xF0 020010 Desc ="FKARC1- Filter constant for fast manifold filling. Calculate this using the equation: Constant = (load at WOT / 100) * (engine displacement / manifold volume) / number of cylinders. A typical value for load would be 80% for a stock engine." 020020 Units ="n/a" 020050 SizeInBits =0x10 020100 Address =0xA900 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xD75 000100 Cat0ID =0x12 020005 Title ="Manifold Slow Fill Constant" 020011 DescSize =0xFB 020010 Desc ="FKARCH - Filter constant for slow manifold filling. Calculate this using the equation: Constant = (load at part throttle / 100) * (engine displacement / manifold volume) / number of cylinders. A typical value for load would be 60% for a stock engine." 020020 Units ="n/a" 020050 SizeInBits =0x10 020100 Address =0xA8FE 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x617E 000100 Cat0ID =0x9 020005 Title ="Manual Gearbox Max Decelleration Load for VSS Test" 020011 DescSize =0x7 020010 Desc ="VSLOAD" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xA3FC 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6034 000100 Cat0ID =0x6 020005 Title ="Max RPM for Idle Flag" 020011 DescSize =0xFE 020010 Desc ="IDLRPM - The maximum rpm permissible in order for the Idle Flag to be set when the CT flag is set. If the base target idle speed 'Idle Speed Neutral' (aka NUBASE) and 'Idle Speed Drive' (aka DRBASE) parameters have been altered then adjust this to suit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB0BA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x56A1 000100 Cat0ID =0x6 020005 Title ="Max RPM for Idle Flag Hysteresis" 020011 DescSize =0x4C 020010 Desc ="IDRPMH - Hysteresis for the 'Max RPM for Idle Flag' (aka IDLRPM) parameter." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB0BC 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xD15 000100 Cat0ID =0x9 020005 Title ="Max Time in Hold Test" 020011 DescSize =0x6 020010 Desc ="VIPT3" 020020 Units ="secs" 020100 Address =0xA450 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2B6A 000100 Cat0ID =0x9 020005 Title ="Max TP Gain for VSC Test" 020011 DescSize =0x9 020010 Desc ="VTPLU - " 020020 Units ="counts" 020050 SizeInBits =0x10 020100 Address =0xA456 020150 Flags =0x2 020200 Equation =X/64,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7CCB 000100 Cat0ID =0xF 020005 Title ="MFA Cold Start Delay #1" 020011 DescSize =0x7 020010 Desc ="MFATM1" 020020 Units ="secs" 020100 Address =0xA4CF 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6EB8 000100 Cat0ID =0xF 020005 Title ="MFA Cold Start Delay #2" 020011 DescSize =0x7 020010 Desc ="MFATM4" 020020 Units ="secs" 020100 Address =0xA4D0 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x46F7 000100 Cat0ID =0xF 020005 Title ="MFA Hot Start Delay" 020011 DescSize =0x7 020010 Desc ="MFATM3" 020020 Units ="secs" 020100 Address =0xA4CC 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7382 000100 Cat0ID =0xF 020005 Title ="MFA Min BP for Economy Mode" 020011 DescSize =0x7 020010 Desc ="MPMNBP" 020020 Units ="in Hg" 020100 Address =0xA4EA 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x3B34 000100 Cat0ID =0xF 020005 Title ="MFA Min BP for Economy Mode Hysteresis" 020011 DescSize =0x7 020010 Desc ="MPNBPH" 020020 Units ="in Hg" 020100 Address =0xA4EB 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5345 000100 Cat0ID =0xF 020005 Title ="MFA MPH Min" 020011 DescSize =0x2D 020010 Desc ="VSMPG - Minimum speed to remain in MFA mode." 020020 Units ="mph" 020100 Address =0xA318 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5346 000100 Cat0ID =0xF 020005 Title ="MFA MPH Hysteresis" 020011 DescSize =0x7 020010 Desc ="VSMPGH" 020020 Units ="mph" 020100 Address =0xA319 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x685C 000100 Cat0ID =0xF 020005 Title ="MFA Ramp Increment" 020011 DescSize =0x7 020010 Desc ="MFARMP" 020020 Units ="n/a" 020100 Address =0xA4EC 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1F9 000100 Cat0ID =0xF 020005 Title ="MFA State Constant RPM Entry Condition" 020011 DescSize =0x6 020010 Desc ="MFASN" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA4DC 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5964 000100 Cat0ID =0xF 020005 Title ="MFA State EGO Switch Requirement" 020011 DescSize =0x55 020010 Desc ="SWTCNT - The minimum number of HEGO switches required for the MFA timer to count up." 020020 Units ="no." 020100 Address =0xA4E 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x198B 000100 Cat0ID =0xF 020005 Title ="MFA State Max Load Condition" 020011 DescSize =0x6 020010 Desc ="MFALH" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xA4DE 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x69AD 000100 Cat0ID =0xF 020005 Title ="MFA State Max Load Condition Hysteresis" 020011 DescSize =0x7 020010 Desc ="MFALHH" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xA4E8 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x8FE 000100 Cat0ID =0xF 020005 Title ="MFA State Max RPM" 020011 DescSize =0x7 020010 Desc ="MFANHI" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA4DA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2FDE 000100 Cat0ID =0xF 020005 Title ="MFA State Max RPM Hysteresis" 020011 DescSize =0x7 020010 Desc ="MFANHH" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA4E2 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4537 000100 Cat0ID =0xF 020005 Title ="MFA State Min Load" 020011 DescSize =0x6 020010 Desc ="MFALL" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0xA4DE 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x54AB 000100 Cat0ID =0xF 020005 Title ="MFA State Min RPM" 020011 DescSize =0x7 020010 Desc ="MFANLO" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA4D8 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x54DE 000100 Cat0ID =0xF 020005 Title ="MFA State Min RPM Hysteresis" 020011 DescSize =0x7 020010 Desc ="MFANLH" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA4DC 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x248D 000100 Cat0ID =0xF 020005 Title ="MFA Warm Start Delay #1" 020011 DescSize =0x7 020010 Desc ="MFATM2" 020020 Units ="secs" 020100 Address =0xA4CD 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x359B 000100 Cat0ID =0xF 020005 Title ="MFA Warm Start Delay #2" 020011 DescSize =0x7 020010 Desc ="MFATM5" 020020 Units ="secs" 020100 Address =0xA4CE 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x360F 000100 Cat0ID =0xB 020005 Title ="MIL Delay Time" 020011 DescSize =0x5C 020010 Desc ="FMDTM - Malfunction indicator light delay time before turning on after a fault is detected." 020020 Units ="secs" 020100 Address =0xA400 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3A1C 000100 Cat0ID =0xB 020005 Title ="MIL Frequency" 020011 DescSize =0x62 020010 Desc ="MILTM1 - The malfunction indicator light will flash at the frequency defined by 1 / (2 * MILTM1)." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xA404 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5158 000100 Cat0ID =0x4 020005 Title ="Min PIP Period RPM (4 cyl)" 020011 DescSize =0xB4 020010 Desc ="MNPIP4 - RPM at which the ecu determines the PIP signal to be unreliable. PIP inputs are ignored above this value. Set slightly higher than 'Rev Limit Set RPM' (aka NLM_SH) limit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA04C 020150 Flags =0x2 020200 Equation =12500000/X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1DAE 000100 Cat0ID =0x4 020005 Title ="Min PIP Period RPM (6 cyl)" 020011 DescSize =0xB4 020010 Desc ="MNPIP6 - RPM at which the ecu determines the PIP signal to be unreliable. PIP inputs are ignored above this value. Set slightly higher than 'Rev Limit Set RPM' (aka NLM_SH) limit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA04E 020150 Flags =0x2 020200 Equation =9375000/X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x52A8 000100 Cat0ID =0x4 020005 Title ="Min PIP Period RPM (8 cyl)" 020011 DescSize =0xB4 020010 Desc ="MNPIP8 - RPM at which the ecu determines the PIP signal to be unreliable. PIP inputs are ignored above this value. Set slightly higher than 'Rev Limit Set RPM' (aka NLM_SH) limit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA050 020150 Flags =0x2 020200 Equation =2809296/X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2346 000100 Cat0ID =0x1 020005 Title ="Min Time for Lugging O/L" 020011 DescSize =0x64 020010 Desc ="LDLTM - The minimum time in lugging mode required for the 'Lugging O/L Flag' (aka LDFLG) to be set." 020020 Units ="secs" 020100 Address =0xAD8B 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x683A 000100 Cat0ID =0x1 020005 Title ="Min Time for Lugging O/L After Startup" 020011 DescSize =0x8E 020010 Desc ="LDTM - The minimum time after startup in lugging mode required for the Lugging O/L Flag to be set.\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="secs" 020100 Address =0xAD8A 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1502 000100 Cat0ID =0x9 020005 Title ="Min TP Gain for VSC Test" 020011 DescSize =0x9 020010 Desc ="VTPLD - " 020020 Units ="counts" 020050 SizeInBits =0x10 020100 Address =0xA454 020150 Flags =0x2 020200 Equation =X/64,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7566 000100 Cat0ID =0x3 020005 Title ="MPH Average Time Constant" 020011 DescSize =0xDD 020010 Desc ="TCVS - The time constant for the rolling average calculation of the 'MPH Average' (aka VSBAR) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADD2 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x457A 000100 Cat0ID =0x3 020005 Title ="MPH Time Constant" 020011 DescSize =0xD4 020010 Desc ="TCMPH - The time constant for the rolling average calculation of the 'MPH' (aka MPH) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADDA 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x59EF 000100 Cat0ID =0xB 020005 Title ="Neutral Drive Switch Min" 020011 DescSize =0x5 020010 Desc ="VND1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA406 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4DE9 000100 Cat0ID =0xB 020005 Title ="Neutral Drive Switch Max" 020011 DescSize =0x5 020010 Desc ="VND2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA408 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%TABLE%% 000002 UniqueID =0x6149 000100 Cat0ID =0x1 040005 Title ="Accel Enrichment Fuel" 040011 DescSize =0x7 040010 Desc ="FN1303" 040100 Address =0xA6BF 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =100.0000 040300 Rows =0x7 040305 Cols =0x8 040320 XUnits ="deg/sec rate" 040325 YUnits ="deg F" 040330 ZUnits ="lb/min" 040350 XLabels = 17, 32, 47, 62, 77, 92,107,122 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =-50, 0, 50,100,150,200,250 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3CD7 040505 XLabelSource =0x2 040510 YLabelLink =0x18ED 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x18ED 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Accel Enrichment Fuel Scaler for ACT to ECT" 040011 DescSize =0x82 040010 Desc ="FN020B - Do not edit first or last entries. Provides row scaling for the following table;\r\n\r\n'Accel Enrichment Fuel' (aka FN1303)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =Table Row Index 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0xA10A 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA10B 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%FLAG%% 000002 UniqueID =0x3022 000100 Cat0ID =0xA 030005 Title ="Adaptive Control Idle Low RPM" 030011 DescSize =0xF6 030010 Desc ="HCAMSW - Clear for the adaptive idle fuel cells to used as soon as the filtered airmass region is entered. Set for the adaptive idle fuel cells to used only when in the filtered airmass region and there are no base idle rpm adders being applied." 030100 Address =0xB0FE 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x2410 000100 Cat0ID =0x7 030005 Title ="Air Charge Switch" 030011 DescSize =0x93 030010 Desc ="ARCHSW - Selects the method of calculating the filtered air charge value. Set to use manifold filling compensation otherwise no filtering is used." 030100 Address =0xA904 030200 BitNumber =0x0 %%END%% %%TABLE%% 000002 UniqueID =0x3CD7 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Accel Enrichment Fuel Scaler for Throttle Rate" 040011 DescSize =0x85 040010 Desc ="FN019B - Do not edit first or last entries. Provides column scaling for the following table;\r\n\r\n'Accel Enrichment Fuel' (aka FN1303)" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="deg/sec" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =Table Column Index 040352 XLabelType =0x4 040354 XEq =X/2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0xA100 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA101 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xFF3 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Accel Enrichment Multiplier for BP" 040011 DescSize =0xFB 040010 Desc ="FN378 - A multiplier of the result of the 'Accel Enrichment Fuel' table lookup after the 'Accel Enrichment Multiplier for TP' (aka FN331B) multiplier has been applied.\r\n\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xA208 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA209 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5016 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Accel Enrichment Multiplier for TP" 040011 DescSize =0xC6 040010 Desc ="FN331B - A multiplier of the result of the 'Accel Enrichment Fuel' table lookup for the relative throttle position.\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Throttle Position,Accelerator Enrichment Multiplier 040352 XLabelType =0x4 040354 XEq =X/12800*256,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xA6B5 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA6B6 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5879 000100 Cat0ID =0xA 040005 Title ="Adaptive Control Learning Table" 040011 DescSize =0x33B 040010 Desc ="FN1325 - Specifies the number of background loop counts that must occur before an adaptive update can happen. Any positive values shown are actually half that of the number of loop counts required. Positive values or zero permit adaptive update to occur in the cell, higher values reduce the update rate. Negative values force the ecu to use a different cell, e.g. -24 indicates that the cell located at row 2, column 4 should be used. Note: rows and columns commence their numbering at zero.\r\n\r\nThe top row is for used for the special idle adaptive cells (the first four entries only as the others are ignored) and are assigned as follows;\r\n\r\nColumn 0 - in drive, A/C off (automatic transmissions only)\r\nColumn 1 - in drive, A/C on (automatic transmissions only)\r\nColumn 2 - in neutral, A/C off\r\nColumn 3 - in neutral, A/C on" 040100 Address =0xB404 040150 Flags =0x1 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040205 OutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x9 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="" 040350 XLabels =(null),(null),(null),(null),(null),(null),(null),(null),(null),(null) 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =(null),(null),(null),(null),(null),(null),(null),(null),(null) 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x5130 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5130 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Adaptive & MAF Backflow Scaler for Load" 040011 DescSize =0xA7 040010 Desc ="FN021 - Do not edit first or last entries. Provides row scaling for the following tables;\r\n\r\n'Adaptive Control Learning Table' (aka FN1325)\r\n'MAF Backflow Correction'" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="load" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =Raw Load,Table Row (Y) Index 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xA114 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA116 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6C08 000100 Cat0ID =0x4 000101 Cat1ID =0xFF 040005 Title ="Air Charge Maximum" 040011 DescSize =0x1C7 040010 Desc ="FN037 - The maximum instantaneous air charge value the engine can hold for a given rpm. The calculated instantaneous air charge value is clipped to this. Typically the output column values are set to the maximum on boosted engines and those that have very high volumetric efficiencies.\r\n\r\nTo calculate how this clip relates to airmass flow for differing rpms use the following calculation;\r\n\r\nkg/hr = FN037 * number of cylinders / 2 * rpm * 60 / 2.20462 " 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xA 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="lb/intake" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16777216,TH|0|0|0|0| 040600 XAddress =0xA6F8 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA6FA 040750 YOutputDig =0x7 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xF2F 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Altitude Multiplier vs BP" 040011 DescSize =0xD9 040010 Desc ="FN129A - Used in altitude spark and lugging open loop fuel calculations. Should be set to 1.000 at high altitudes and 0.000 at sea level. Values must overlap with the 'Sea Level Multiplier vs BP' (aka FN212A) table. " 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xAAC6 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAAC7 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x51B 000100 Cat0ID =0x3 000101 Cat1ID =0xFF 040005 Title ="BAP Transfer" 040011 DescSize =0x6 040010 Desc ="FN000" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="in Hg" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/12800,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/2048,TH|0|0|0|0| 040600 XAddress =0xA0DA 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA0DC 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2481 000100 Cat0ID =0xD 000101 Cat1ID =0xFF 040005 Title ="Canister Purge Dutycycle Multiplier #1" 040011 DescSize =0x6 040010 Desc ="FN600" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="secs" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xB036 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB037 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x595B 000100 Cat0ID =0xD 000101 Cat1ID =0xFF 040005 Title ="Canister Purge Dutycycle Multiplier #2" 040011 DescSize =0x6 040010 Desc ="FN602" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="secs" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xB042 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB043 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1DD1 000100 Cat0ID =0xD 000101 Cat1ID =0xFF 040005 Title ="Canister Purge Dutycycle vs Airmass" 040011 DescSize =0xA 040010 Desc ="FN605A - " 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="lb" 040325 YUnits ="dutycycle" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/1.28,TH|0|0|0|0| 040600 XAddress =0xB04E 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB04F 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xEF8 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Cold Engine Fuel Multiplier Update Time" 040011 DescSize =0x166 040010 Desc ="FN393F - When the 'Cold Engine Fuel Multiplier Update Timer' (aka MULTMR) exceeds this parameter's lookup value then the 'Cold Engine Fuel Multiplier' (aka LAMMUL) value is updated.\r\n\r\nThe 'Cold Engine Fuel Multiplier' (aka LAMMUL) value is used to prevent stalling during drive engagement when the engine is cold (automatic gearbox equipped vehicles only)." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="secs" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040600 XAddress =0xA07A 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA07B 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x793A 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Cranking Fuel PW Multiply vs Time" 040011 DescSize =0x52 040010 Desc ="FN306 - Multiplies cranking fuel pulsewidth according to length of cranking time." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="sec" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16384,TH|0|0|0|0| 040600 XAddress =0xAE3E 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAE40 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4084 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Cranking Fuel PW vs ECT" 040011 DescSize =0xBA 040010 Desc ="FN348 - The injector pulsewidth during cranking at sea level. Alter for injector and cam swaps. For larger injectors reduce the pulsewidth by the ratio of the low injector slope change." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x9 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="mSecs" 040330 ZUnits ="" 040350 XLabels =Engine Coolant Temperature,Pulsewidth 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/262.144,TH|0|0|0|0| 040600 XAddress =0xAE56 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAE58 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x44A7 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="CT Drive Fuel Multiplier vs RPM" 040011 DescSize =0xEF 040010 Desc ="FN301 - Open loop mode multiplier that adjusts the desired A/F ratio when the throttle is closed, the gearbox is in drive and no HEGO switches have occurred.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xB158 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB15A 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x551E 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="CT Neutral Fuel Multiplier vs RPM" 040011 DescSize =0xD2 040010 Desc ="FN301N - Open loop mode multiplier that adjusts the desired A/F ratio when the throttle is closed and the gearbox is in neutral.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xB170 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB172 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1A00 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="CT Neutral Timer RPM Adder" 040011 DescSize =0x10C 040010 Desc ="FN880 - The results of this table are used in two ways:\r\n\r\ni) The result of this lookup is used to increase desired idle rpm when the 'CT Neutral Flag (aka CTNFLG) is set.\r\n\r\nii) The result of this lookup is added to the 'CT Neutral Timer Max RPM' (aka INLRPM) value." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="secs" 040325 YUnits ="rpm" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*8,TH|0|0|0|0| 040600 XAddress =0xAB28 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAB29 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5880 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="CT Spark Adder for ECT" 040011 DescSize =0x31 040010 Desc ="FN112 - Added to 'CT Spark vs RPM' lookup value." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0xC0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0xAA8E 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAA8F 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x40BC 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="CT Spark Subtractor for BP" 040011 DescSize =0x6E 040010 Desc ="FN115 - Subtracted from 'CT Spark vs RPM' lookup value at startup to heat up the catalytic convertor quicker." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x80 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0xAA9C 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAA9D 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7435 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="CT Spark Subtractor for Neutral" 040011 DescSize =0xE1 040010 Desc ="FN180 - When the 'CT Neutral Flag' (aka CTNFLG) is set the result of this table lookup is subtracted from the 'CT Spark vs RPM' lookup value. The input value to this table is the 'Closed Throttle Neutral Timer' (aka CTNTMR)." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="secs" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0xAB1C 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAB1D 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x41FC 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="CT Spark vs RPM" 040011 DescSize =0x3F 040010 Desc ="FN111 - The base spark value used when the throttle is closed." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x3C0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Speed 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0xAA7A 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAA7C 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4D78 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Dashpot Decrement Rate" 040011 DescSize =0x133 040010 Desc ="FN879 - Determines the dashpot (pre position airflow) bleed off rate according to the current dashpot value. During closed throttle mode the dashpot airflow is bled off by decrementing it in order to smooth the transition into rpm control by slowly eliminating the dashpot contribution to the idle airflow." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels =Dashpot,Decrement Rate 040352 XLabelType =0x4 040354 XEq =X/4096,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4096,TH|0|0|0|0| 040600 XAddress =0xA87E 040650 XOutputDig =0x6 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA880 040750 YOutputDig =0x6 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4066 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Dashpot Max Clip" 040011 DescSize =0x4C 040010 Desc ="FN882 - The maximum dashpot (pre position airflow) allowed for a given rpm." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels =RPM,Dashpot Clip 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4096,TH|0|0|0|0| 040600 XAddress =0xA89A 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA89C 040750 YOutputDig =0x6 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1450 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Decel Fuel Shut Off Multiplier" 040011 DescSize =0x143 040010 Desc ="FN374 - Adjusts the desired fuel flow if the conditions required for deceleration fuel shut off have been met.\r\nSet multiplier to 0 to invoke deceleration fuel shut off at desired rpm otherwise set to 1.\r\nWhen in underspeed mode this multiplier value is multiplied by the result of the 'Underspeed Fuel Multiplier' lookup." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =RPM,Open Loop Fuel Multiplier 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xB3EC 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB3EE 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xD23 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Drive Engagement Fuel Multiplier vs ECT" 040011 DescSize =0x12D 040010 Desc ="FN371 - Provides an initial value for the 'Cold Engine Fuel Multiplier' (aka LAMMUL) value which is used to prevent stalling during drive engagement when the engine is cold (automatic gearbox equipped vehicles only). \r\n\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X/128,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xB2CC 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB2CE 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x648C 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Dwell Time Low Temperature" 040011 DescSize =0xAB 040010 Desc ="FN160A - Used when the estimated coil temperature is less than or equal to the 'Dwell Time Table Select Temperature' (aka DWLTBP) value.\r\n\r\nY conversion might be X/524288" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="mSecs" 040330 ZUnits ="" 040350 XLabels =Battery Voltage,Dwell / Coil Off Time 040352 XLabelType =0x4 040354 XEq =X/16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/512,TH|0|0|0|0| 040600 XAddress =0xAD16 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAD18 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x299 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Dwell Time High Temperature" 040011 DescSize =0xA2 040010 Desc ="FN160B - Used when the estimated coil temperature is greater than the 'Dwell Time Table Select Temperature' (aka DWLTBP) value.\r\n\r\nY conversion might be X/524288" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="mSecs" 040330 ZUnits ="" 040350 XLabels =Battery Voltage,Dwell / Coil Off Time 040352 XLabelType =0x4 040354 XEq =X/16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/512,TH|0|0|0|0| 040600 XAddress =0xAD2E 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAD30 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7458 000100 Cat0ID =0x3 000101 Cat1ID =0xFF 040005 Title ="ECT ACT Transfer" 040011 DescSize =0x33 040010 Desc ="FN703A - Input is a rough hi byte only conversion." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x80 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xA 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="deg F" 040330 ZUnits ="" 040350 XLabels =Sensor,Temperature 040352 XLabelType =0x4 040354 XEq =X/64,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*2,TH|0|0|0|0| 040600 XAddress =0xA212 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA213 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1F4 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Altitude Multiplier for BP" 040011 DescSize =0x5B 040010 Desc ="FN217A - A multiplier of the result of the 'EGR Altitude Table' (aka FN908B) table lookup." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xAED4 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAED5 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7875 000100 Cat0ID =0xC 040005 Title ="EGR Altitude Table" 040011 DescSize =0x7 040010 Desc ="FN908B" 040100 Address =0xAFDA 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =50.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="EGR%" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x79F9 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Desired Drop vs Desired Flow" 040011 DescSize =0x6 040010 Desc ="FN247" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xA 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="in H2O" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/32768,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xAF62 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAF64 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7864 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Dutycycle Adder vs EGR Error" 040011 DescSize =0x9 040010 Desc ="FN239 - " 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x3C0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="adder" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/6400,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/327.68,TH|0|0|0|0| 040600 XAddress =0xAF1E 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAF20 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x196A 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Mass Flow as a Function of DELPR" 040011 DescSize =0x24 040010 Desc ="FN246 - Also called 'EGR Transfer'." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xA 040305 Cols =0x1 040320 XUnits ="in H2O" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/256,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/32768,TH|0|0|0|0| 040600 XAddress =0xAF3A 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAF3C 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3B2B 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Mass Flow vs EGR Valve Position" 040011 DescSize =0x43 040010 Desc ="FN219A - Used when 'EGR Type' (aka PFEHP) parameter is set to '0'." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X*0.02,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xAEE0 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAEE2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x72BA 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Multiplier for ACT" 040011 DescSize =0x6 040010 Desc ="FN220" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =ACT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xAEF8 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAEF9 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x9FF 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Multiplier for ECT" 040011 DescSize =0x6 040010 Desc ="FN211" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xAEBE 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAEBF 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2D5 000100 Cat0ID =0xC 040005 Title ="EGR Sea Level Table" 040011 DescSize =0x7 040010 Desc ="FN908A" 040100 Address =0xAF8A 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =50.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="EGR%" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x25B5 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Valve Position vs Desired Flow" 040011 DescSize =0x6 040010 Desc ="FN221" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="volts" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/128,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*0.02,TH|0|0|0|0| 040600 XAddress =0xAF02 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAF04 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x63B2 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Valve Upstream Pressure" 040011 DescSize =0x40 040010 Desc ="FN074 - Upstream pressure as a function of input (AM * KAMREF)." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xA 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="in H2O" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/2048,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xAE96 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAE98 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5D5C 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Emission Scaler for RPM" 040011 DescSize =0xB3 040010 Desc ="FN039 - Do not edit first or last entries. Provides column scaling for the following tables;\r\n\r\n'HEGO Amplitude' (aka FN1352)\r\n'HEGO Bias' (aka FN1353)\r\n'HEGO Delay' (aka FN1351)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xB114 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB116 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x618F 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Emissions & Spark Scaler for Load" 040011 DescSize =0x1BE 040010 Desc ="FN071 - Do not edit first or last entries. Provides row scaling for the following tables;\r\n\r\n'EGR Altitude Table'\r\n'EGR Sea Level Table'\r\n'Equilibrium Fuel Time Constant'\r\n'Equilibrium Intake Surface Fuel'\r\n'HEGO Amplitude' (aka FN1352)\r\n'HEGO Bias' (aka FN1353)\r\n'HEGO Delay' (aka FN1351)\r\n'PT Spark Adder for ECT and Load'\r\n'PT Spark Adder for EGR'\r\n'Spark Altitude Table'\r\n'Spark Base Table'\r\n'Spark Sea Level Table'\r\n'Torque Reduction Table'" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="load" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xA15C 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA15E 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3661 000100 Cat0ID =0x12 040005 Title ="Equilibrium Fuel Time Constant" 040011 DescSize =0x1E8 040010 Desc ="FN1322 - Effects the amount of contribution the transient fuel makes to the injection pulsewidth where;\r\n\r\nSmaller values increases the amount resulting in richer A/F ratios during accelerations.\r\nLarger values decreases the amount resulting in leaner A/F ratios during accelerations.\r\n\r\nThe column input value is the ratio of ACT to ECT where the ACT contribution is defined by the 'ACT Fraction for Transient Fuel' (aka ALPHA) parameter. \r\n\r\nConversion might be X/32, to be determined." 040100 Address =0xB33C 040200 ZEq =X/8,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =0.0000 040240 RangeHigh =100.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="deg F" 040325 YUnits ="Load" 040330 ZUnits ="secs" 040350 XLabels =-30, 0, 30, 60, 90,120,150,180,210,240 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3CB1 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x476A 000100 Cat0ID =0x12 040005 Title ="Equilibrium Intake Surface Fuel" 040011 DescSize =0xA8 040010 Desc ="FN1321 - \r\n\r\nThe column input value is the ratio of ACT to ECT where the ACT contribution is defined by the 'ACT Fraction for Transient Fuel' (aka ALPHA) parameter. \r\n" 040100 Address =0xB2EC 040200 ZEq =X/4096,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x4 040230 RangeLow =0.0000 040240 RangeHigh =300.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="deg F" 040325 YUnits ="load" 040330 ZUnits ="lb/min" 040350 XLabels = 4000, 3000, 2500, 2000, 1500, 1300, 1100, 900, 700, 500 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3CB1 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x409B 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="Exhaust Back Pressure Correction" 040011 DescSize =0xFA 040010 Desc ="FN004 - Used in the exhaust pressure calculation to compensate for exhaust pressure only increasing at half the rate that barometric pressure increases. You should not need change this as it is a correction derived from pressure chamber experiments." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="in Hg" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/8,TH|0|0|0|0| 040600 XAddress =0xAE8C 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAE8D 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x43D6 000100 Cat0ID =0xB 040005 Title ="Failed MAF Sensor" 040011 DescSize =0x7D 040010 Desc ="FN1358 - Substitution instantaneous air charge value at sea level used if the MAF sensor has failed and the TP sensor is ok." 040100 Address =0xA5F6 040200 ZEq =X/131072,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x8 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x7 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="volts - TP relative" 040330 ZUnits ="lb" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 0,3200,6400,12800,19200,25600,32000 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x29C8 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4158 000100 Cat0ID =0xB 000101 Cat1ID =0xFF 040005 Title ="Failed MAF Sensor Alternative" 040011 DescSize =0x8B 040010 Desc ="FN040 - Substitution instantaneous air charge value used if both the MAF and TP sensors have failed.\r\n\r\nOutput conversion to be confirmed." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="lb/intake" 040330 ZUnits ="" 040350 XLabels =Speed,Y 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16777216,TH|0|0|0|0| 040600 XAddress =0xA5D6 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA5D8 040750 YOutputDig =0x7 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3987 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Fuel and Spark Scaler for RPM" 040011 DescSize =0x98 040010 Desc ="FN083 - Do not edit first or last entries. Provides column scaling for the following tables;\r\n\r\n'MFA EGR Multiplier'\r\n'MFA PT Spark Adder' (aka FN1124)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x4 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =Speed,Table Index 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xA1A8 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA1AA 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x13EF 000100 Cat0ID =0x1 040005 Title ="Fuel Base Table" 040011 DescSize =0xC4 040010 Desc ="FN1307 - Used when in open loop mode.\r\n\r\nThe column input value is the ratio of ACT to ECT where the ACT contribution is defined by the 'ACT Fraction for Fuel Base Table' (aka FRCBFT) parameter. " 040100 Address =0xB1F4 040200 ZEq =X/128*14.64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =8.0000 040240 RangeHigh =18.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="deg F" 040325 YUnits ="load%" 040330 ZUnits ="A/F Ratio" 040350 XLabels =(null),(null),(null),(null),(null),(null),(null),(null),(null),(null) 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =(null),(null),(null),(null),(null),(null),(null),(null) 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3CB1 040505 XLabelSource =0x2 040510 YLabelLink =0x6012 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5567 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Fuel Lugging Altitude Multiplier" 040011 DescSize =0xA4 040010 Desc ="FN309 - Open loop mode multiplier that adjusts the desired A/F ratio when lugging.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xAE22 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAE24 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x16B2 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Fuel Lugging Sea Level Multiplier" 040011 DescSize =0xA4 040010 Desc ="FN308 - Open loop mode multiplier that adjusts the desired A/F ratio when lugging.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xAE06 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAE08 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6EC3 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Fuel Multiplier vs ACT" 040011 DescSize =0xD2 040010 Desc ="FN300 - Open loop multiplier applied to the result of the 'Fuel Base Table' (aka FN1307) lookup to adjust the desired A/F ratio.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Intake Air ChargeTemp,Open Loop Fuel Multiplier 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/64,TH|0|0|0|0| 040600 XAddress =0xB14C 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB14D 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3CB1 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Fuel Scaler for ACT to ECT" 040011 DescSize =0x103 040010 Desc ="FN022 - Do not edit first or last entries. Provides column scaling for the following tables;\r\n\r\n'Equilibrium Fuel Time Constant' (aka FN1322) \r\n'Equilibrium Intake Surface Fuel' (aka FN1321)\r\n'Fuel Base Table' (aka FN1307)\r\n'Fuel Startup Table' (aka FN1306)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =ECT/ACT,Map Index 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0xA134 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA135 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6012 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Fuel Scaler for Load%" 040011 DescSize =0xA7 040010 Desc ="FN072A - Do not edit first or last entries. Provides row scaling for the following tables;\r\n\r\n'Fuel Base Table' (aka FN1307)\r\n'MFA Fuel Multiplier Table' (aka FN1328)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="load%" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =Load,Table Row Index 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0xA178 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA17A 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x44B7 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Fuel Startup Scaler for Time" 040011 DescSize =0x71 040010 Desc ="FN018 - Do not edit first or last entries. Provides row scaling for the following table;\r\n\r\n'Fuel Startup Table'" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="sec" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =Time,Table Column Index 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0xA0F2 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA0F3 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6A64 000100 Cat0ID =0x1 040005 Title ="Fuel Startup Table" 040011 DescSize =0x14B 040010 Desc ="FN1306 - Subtracted from 'Fuel Base Table' for start up enrichment.\r\n\r\nWarning: The top row must always contain zeros to prevent post warmup enrichment still occuring.\r\n\r\nThe column input value is the ratio of ACT to ECT where the ACT contribution is defined by the 'ACT Fraction for Fuel Startup Table' (aka FRCSFT) parameter. \r\n" 040100 Address =0xB244 040200 ZEq =X/128*14.64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =0.0000 040240 RangeHigh =10.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="deg F" 040325 YUnits ="secs" 040330 ZUnits ="A/F Ratio" 040350 XLabels =-30, 0, 30, 60, 90,120,150,180,210,240 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 0, 3, 6, 10, 15, 25, 35, 45 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3CB1 040505 XLabelSource =0x2 040510 YLabelLink =0x44B7 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x68EC 000100 Cat0ID =0x3 040005 Title ="HEGO Amplitude" 040011 DescSize =0xED 040010 Desc ="FN1352 - The maximum A/F ratio deviation (plus or minus) from stoichiometric that the A/F ratio oscillates between to form the rich and lean limits of closed loop fueling. The output value is referred to as the 'Peak to Peak Amplitude'." 040100 Address =0xB3AC 040200 ZEq =X/512*14.64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =0.1000 040300 Rows =0x8 040305 Cols =0x4 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="A/F ratio" 040350 XLabels = 700, 900,1950,3000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x5D5C 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x61FA 000100 Cat0ID =0x3 040005 Title ="HEGO Bias" 040011 DescSize =0x120 040010 Desc ="FN1353 - These correction values are used to shift the averaged closed loop A/F ratio slightly away from stoichiometric to adjust emissions. \r\n\r\nPositive bias values will lean the A/F ratio (raise NOx but lower CO)\r\nNegative bias values will richen the A/F ratio (lower NOx but raise CO)" 040100 Address =0xB3CC 040150 Flags =0x1 040200 ZEq =X/2048*14.64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =-0.0200 040240 RangeHigh =0.0200 040300 Rows =0x8 040305 Cols =0x4 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="A/F ratio" 040350 XLabels = 700, 900,1950,3000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x5D5C 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x70C2 000100 Cat0ID =0x3 040005 Title ="HEGO Delay" 040011 DescSize =0x194 040010 Desc ="FN1351 - The time delay in revs per second from when a fuel change is made until the HEGO sensor detects this change. Prevents electrical noise in the system being incorrectly interpreted as a HEGO switch. Increase when the HEGO sensor is installed farther downstream from stock position. The result from this table lookup is used to calculate the exhaust pulse transport delay in both PIPs and seconds." 040100 Address =0xB38C 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =20.0000 040300 Rows =0x8 040305 Cols =0x4 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="rev per sec" 040350 XLabels = 700, 900,1950,3000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x5D5C 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7A0F 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="HEGO Delay PIP Multiplier" 040011 DescSize =0x116 040010 Desc ="FN346 - A multiplier of the exhaust pulse transport delay in PIPs value used to calculate the expected number of PIPs that will occur before the HEGO detects a change in fueling.\r\n\r\nnb The input value of 'Bias/Peak to Peak Amplitude' is clamped to a maximum of 0.45 by the eec." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xB 040305 Cols =0x1 040320 XUnits ="bias/ptpamp" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/512,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0xA1F2 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA1F3 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x739C 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="HEGO Jumpback Multiplier with Bias" 040011 DescSize =0x312 040010 Desc ="FN344 - When a HEGO switch occurs during closed loop fuelling this is used as a multiplier of the sum of the 'Bias' and 'Peak to Peak Amplitude' (aka PTPAMP) values to determine the amount the desired A/F ratio should jumpback towards the averaged A/F ratio by.\r\n\r\nUsed when either of the two following conditions are met;\r\ni) the HEGO is reporting lean and the 'Bias' is rich (a negative value)\r\nii) the HEGO is reporting rich and the 'Bias' is lean (a positive value) or zero\r\notherwise the 'HEGO Jumpback Multiplier without Bias' (aka FN342) parameter is used.\r\n\r\nNotes:\r\n1) Larger Bias values result in smaller jumpback values.\r\n2) Do not enter multiplier values greater than '1.000'.\r\n3) The input value of 'Bias/Peak to Peak Amplitude' is clamped to a maximum of 0.45 by the eec." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="bias/ptpamp" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/512,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xA1E8 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA1E9 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5AE 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="HEGO Jumpback Multiplier without Bias" 040011 DescSize =0x31B 040010 Desc ="FN342 - When a HEGO switch occurs during closed loop fuelling this is used as a multiplier of the 'Peak to Peak Amplitude' (aka PTPAMP) value to determine the amount the desired A/F ratio should jumpback towards the averaged A/F ratio by.\r\n\r\nUsed when either of the two following conditions are met;\r\ni) the HEGO is reporting lean and the 'Bias' is lean (a positive value) or zero\r\nii) the HEGO is reporting rich and the 'Bias' is rich (a negative value)\r\notherwise the 'HEGO Jumpback Multiplier with Bias' (aka FN344) parameter is used.\r\n\r\nNotes:\r\n1) Larger Bias values result in smaller jumpback values.\r\n2) Do not enter multiplier values greater than '1.000'.\r\n3) Do not alter the top two rows.\r\n4) The input value of 'Bias/Peak to Peak Amplitude' is clamped to a maximum of 0.45 by the eec." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="bias/ptpamp" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/512,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xA1DA 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA1DB 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x69DC 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="HEGO Ramp Rate Multiplier" 040011 DescSize =0x192 040010 Desc ="FN339 - During closed loop fuelling this table determines the rate at which the desired A/F ratio ramps richer or leaner towards the HEGO switch point. As the values in this table are very important for getting the fast and slow ramp rates correct when a Bias is used it should not normally be altered.\r\n\r\nnb The input value of 'Bias/Peak to Peak Amplitude' is clamped to a maximum of 0.45 by the eec." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="bias/ptpamp" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =X 040352 XLabelType =0x4 040354 XEq =X/512,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xA1D0 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA1D1 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x43B5 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="High Speed Fuel Multiplier" 040011 DescSize =0x10C 040010 Desc ="FN396A - Open loop multiplier that adjusts the desired A/F ratio when the 'Speed Limiter Stage One On' threshold is exceeded.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel.\r\nSet to 0.996 when 'High Speed Spark Retard' is set to zero." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="mph" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xADF7 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xADF8 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x253D 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="High Speed Spark Retard" 040011 DescSize =0xA6 040010 Desc ="FN179A - Deducted from PT and WOT spark calculations when the 'Speed Limiter Stage One On' threshold is exceeded. If set to zero adjust 'High Speed Fuel Multiplier'." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="mph" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0xADE9 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xADEA 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x20ED 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Adder for ACT" 040011 DescSize =0x7 040010 Desc ="FN825B" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="rpm" 040330 ZUnits ="" 040350 XLabels =ACT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*8,TH|0|0|0|0| 040600 XAddress =0xA266 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA267 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3F90 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Adder for ECT" 040011 DescSize =0x7 040010 Desc ="FN825A" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="rpm" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*8,TH|0|0|0|0| 040600 XAddress =0xA256 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA257 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6A16 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Airflow Drive" 040011 DescSize =0xBC 040010 Desc ="FN875D - The predicted idle airflow required to achieve the desired idle rpm when in drive at closed throttle.\r\n\r\nAlter if the air flow characteristics through the ISC valve have changed." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="desired rpm" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xA8E4 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA8E5 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x133E 000100 Cat0ID =0x6 040005 Title ="Idle Airflow Multiplier" 040011 DescSize =0x58 040010 Desc ="FN1861 - A multiplier of predicted idle airflow to adjust for ECT and time in run mode." 040100 Address =0xA8BA 040200 ZEq =X/64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x6 040305 Cols =0x7 040320 XUnits ="deg F" 040325 YUnits ="secs" 040330 ZUnits ="multiplier" 040350 XLabels =-50, 0, 50,100,150,200,250 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 0, 3, 5, 10, 20, 30 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0xE7D 040505 XLabelSource =0x2 040510 YLabelLink =0x10B5 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6E83 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Airflow Neutral" 040011 DescSize =0xBE 040010 Desc ="FN875N - The predicted idle airflow required to achieve the desired idle rpm when in neutral at closed throttle.\r\n\r\nAlter if the air flow characteristics through the ISC valve have changed." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="desired rpm" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xA8F0 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA8F1 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x835 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle RPM Error Spark Multiplier Drive" 040011 DescSize =0xCD 040010 Desc ="FN841D - Aggressive closed throttle spark modifier used when in idle 'rpm control' or 'rpm lockout' mode. Outputs a spark multiplier to assist in the correction of any deviation from the desired idle rpm." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm delta" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xA82A 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA82C 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1C14 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle RPM Error Spark Multiplier Neutral" 040011 DescSize =0xCD 040010 Desc ="FN841N - Aggressive closed throttle spark modifier used when in idle 'rpm control' or 'rpm lockout' mode. Outputs a spark multiplier to assist in the correction of any deviation from the desired idle rpm." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm delta" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xA846 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA848 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3109 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Spark Multiplier vs Dashpot" 040011 DescSize =0xD0 040010 Desc ="FN839 - Closed throttle spark modifier used when in idle 'dashpot control' mode following the transition from part throttle. Outputs a spark multiplier to assist in the stabilisation of the desired idle rpm." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x4 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/64,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xA822 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x6 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA823 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4587 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Startup Adder" 040011 DescSize =0x86 040010 Desc ="FN826A - Adds rpm to 'Desired Idle RPM' at startup for the duration specified by the 'Idle Startup Adder Time' (aka TKDTM) parameter." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F at start" 040325 YUnits ="rpm" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*8,TH|0|0|0|0| 040600 XAddress =0xA814 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA815 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1284 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Injector Breakpoint" 040011 DescSize =0x265 040010 Desc ="FN389 - The returned lookup value is multiplied by the rpm / 2 to determine the intersection point of the two injector slopes. If the desired fuel flow for a bank is less than or equal to this calculated value then only the 'Injector Low Slope' is used for the calculation of the injection pulsewidth otherwise both injector slopes are used. Use to correct AF ratio at idle when the Long Term Fuel Trims indicate adjustment is required by increasing the value to reduce fuel from the final calculated fuel pulsewidth. Has a diminishing effect from idle up to approximately 1500 rpm. Y conversion to be confirmed." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="lb/rev" 040330 ZUnits ="" 040350 XLabels =Battery Voltage 040352 XLabelType =0x4 040354 XEq =X/4096,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/268435456,TH|0|0|0|0| 040600 XAddress =0xA720 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA722 040750 YOutputDig =0xA 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x64CC 000100 Cat0ID =0x7 040005 Title ="Injector Firing Order" 040011 DescSize =0x7 040010 Desc ="FN1329" 040100 Address =0xA6AD 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x0 040230 RangeLow =0.0000 040240 RangeHigh =10.0000 040300 Rows =0x1 040305 Cols =0x8 040320 XUnits ="Injector to Fire" 040325 YUnits ="cylinder" 040330 ZUnits ="injector no." 040350 XLabels =-,-,-,-,-,-,-,- 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =cylinder 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x406D 000100 Cat0ID =0x7 000101 Cat1ID =0xFF 040005 Title ="Injector Offset vs Voltage" 040011 DescSize =0xB5 040010 Desc ="FN367 - Extra duration added to injector pulsewidth to compensate for battery voltage. Reduce for larger injectors by the ratio of the injector change. Curve should be exponential." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xC 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="mSecs" 040330 ZUnits ="" 040350 XLabels =Battery Voltage,Injector Offset 040352 XLabelType =0x4 040354 XEq =X/16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/32,TH|0|0|0|0| 040600 XAddress =0xB134 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB135 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%CONSTANT%% 000002 UniqueID =0x213E 000100 Cat0ID =0x7 020005 Title ="Number of Cylinders" 020011 DescSize =0x287 020010 Desc ="NUMCYL - If altered then the 'Engine Displacement' (aka SARCHG) conversion equation will need altering. The following parameters will need altering too:\r\n\r\n'Ignition Degrees Per PIP' (aka DEGPIP)\r\n'Injector Firing Order' (aka FN1329)\r\n'Injector Output Port' (aka FN1327)\r\n'Manifold Fast Fill Constant' (aka FKARC1)\r\n'Manifold Slow Fill Constant' (aka FKARCH)\r\n'Number of Injector Output Ports' (aka NUMOUT)\r\n'Number of PIPs Between Injector Outputs' (aka PIPOUT)\r\n'PIPs per Rev' (aka ENGCYL)\r\n'Signature PIP Difference Value' (aka MHPFD)\r\n'Signature PIP Multiplier Highest Value' (aka SIGKLU)\r\n'Signature PIP Multiplier Lowest Value' (aka SIGKLL)" 020020 Units ="no." 020050 SizeInBits =0x10 020100 Address =0xB0AC 020150 Flags =0x2 020200 Equation =X/32,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6013 000100 Cat0ID =0x7 020005 Title ="Number of HEGOs" 020011 DescSize =0xA8 020010 Desc ="NUMEGO - Set to the number of hego sensors fitted. If converting from a stereo to a mono hego set up the 'Injector Output Port' (aka FN1327) table will need adjusting." 020020 Units ="no." 020100 Address =0xB47A 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3781 000100 Cat0ID =0x9 020005 Title ="Number of HEGO Switches to Pass Test" 020011 DescSize =0x7 020010 Desc ="VEGOSW" 020020 Units ="no." 020100 Address =0xA37B 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5CCE 000100 Cat0ID =0x7 020005 Title ="Number of Injector Output Ports" 020011 DescSize =0x7 020010 Desc ="NUMOUT" 020020 Units ="no." 020100 Address =0xB0B4 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5FCF 000100 Cat0ID =0x2 020005 Title ="Number of Pips Between Injector Outputs" 020011 DescSize =0x9 020010 Desc ="PIPOUT -" 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0xB0B0 020150 Flags =0x2 020200 Equation =X/32,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x52D8 000100 Cat0ID =0x11 020005 Title ="Off Button Maximum" 020011 DescSize =0x5D 020010 Desc ="HI_OFF - Highest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E6E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52D9 000100 Cat0ID =0x11 020005 Title ="On Button Minimum" 020011 DescSize =0x5C 020010 Desc ="LOW_ON - Lowest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E70 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x108D 000100 Cat0ID =0x2 020005 Title ="PIP Acceleration Limit" 020011 DescSize =0x4C 020010 Desc ="PACLIM - The maximum limit of PIP acceleration in percentage of PIP period." 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0xAA20 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5B3C 000100 Cat0ID =0x2 020005 Title ="PIP Acceleration Offset" 020011 DescSize =0x9 020010 Desc ="PACOFF\r\n" 020020 Units ="(beta-cyl)/rev" 020050 SizeInBits =0x10 020100 Address =0xAA1C 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x31E2 000100 Cat0ID =0x2 020005 Title ="PIP Acceleration Period" 020011 DescSize =0x7 020010 Desc ="PACPER" 020020 Units ="(rev-secs)/cyl" 020050 SizeInBits =0x10 020100 Address =0xAA1A 020150 Flags =0x2 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x563A 000100 Cat0ID =0x9 020005 Title ="PIP IDM Test Min RPM" 020011 DescSize =0x7 020010 Desc ="VLORPM" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA34E 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6530 000100 Cat0ID =0x9 020005 Title ="PIP Fault Time Out" 020011 DescSize =0x7 020010 Desc ="VPIPTM" 020020 Units ="mSecs" 020050 SizeInBits =0x10 020100 Address =0xA350 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B3D 000100 Cat0ID =0x2 020005 Title ="PIP Period Slope" 020011 DescSize =0x78 020010 Desc ="PACSLO - Used in the calculation to determine the percentage of PIP that PIP will decrease during maximum acceleration." 020020 Units ="beta/sec" 020050 SizeInBits =0x10 020100 Address =0xAA1E 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4ACD 000100 Cat0ID =0x5 020005 Title ="PIP Recognition Time Delay" 020011 DescSize =0x3D 020010 Desc ="TKYON1 - Used to ignore any noise in the system at power up." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xAA4E 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5FD0 000100 Cat0ID =0x1 020005 Title ="PIPs per Crank Injector Firing" 020011 DescSize =0xA 020010 Desc ="CRKPIP - " 020020 Units ="no." 020100 Address =0xB0B2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x45E2 000100 Cat0ID =0x7 020005 Title ="PIPs per Rev" 020011 DescSize =0x2F 020010 Desc ="ENGCYL - Number of PIPs per engine revolution." 020020 Units ="pips" 020100 Address =0xB469 020200 Equation =X/2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xE6 000100 Cat0ID =0x2 020005 Title ="PT Spark Adder" 020011 DescSize =0x5 020010 Desc ="KPS1" 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0xAA02 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5AD1 000100 Cat0ID =0x2 020005 Title ="PT Spark Multiplier" 020011 DescSize =0x2 020010 Desc ="Y" 020020 Units ="multiplier" 020100 Address =0xAA0C 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4276 000100 Cat0ID =0xD 020005 Title ="Purge Cold Start Delay #1" 020011 DescSize =0x7 020010 Desc ="PRGTD1" 020020 Units ="secs" 020100 Address =0xA94D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3DDD 000100 Cat0ID =0xD 020005 Title ="Purge Cold Start Delay #2" 020011 DescSize =0x7 020010 Desc ="PRGTD4" 020020 Units ="secs" 020100 Address =0xA94E 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D92 000100 Cat0ID =0xD 020005 Title ="Purge Hot Start Delay" 020011 DescSize =0x7 020010 Desc ="PRGTD3" 020020 Units ="secs" 020100 Address =0xA949 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3B71 000100 Cat0ID =0xD 020005 Title ="Purge Warm Start Delay #1" 020011 DescSize =0x7 020010 Desc ="PRGTD2" 020020 Units ="secs" 020100 Address =0xA94B 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2DC 000100 Cat0ID =0xD 020005 Title ="Purge Warm Start Delay #2" 020011 DescSize =0x7 020010 Desc ="PRGTD5" 020020 Units ="secs" 020100 Address =0xA94C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x58D4 000100 Cat0ID =0xD 020005 Title ="Purge Max ECT" 020011 DescSize =0x45 020010 Desc ="CTPRG - The temperature above which canister purge is not permitted." 020020 Units ="deg F" 020100 Address =0xA941 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x69C 000100 Cat0ID =0xD 020005 Title ="Purge Max ECT Hysteresis" 020011 DescSize =0x7 020010 Desc ="CTPRGH" 020020 Units ="deg F" 020100 Address =0xA942 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x749D 000100 Cat0ID =0xD 020005 Title ="Purge PT and WOT Delay Time" 020011 DescSize =0x7 020010 Desc ="EVTDOT" 020020 Units ="secs" 020100 Address =0xA944 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x347C 000100 Cat0ID =0xD 020005 Title ="Purge Test Disable" 020011 DescSize =0xB1 020010 Desc ="Z_VPRG - Normally this is set to\"7C28\", change to \"420\" to prevent the canister purge solenoid test being performed.\r\n\r\nWARNING: Do not enter any value other than one of these." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x7A13 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DE 000100 Cat0ID =0x11 020005 Title ="Resume Button Minimum" 020011 DescSize =0x5C 020010 Desc ="LRESUM - Lowest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E7A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DF 000100 Cat0ID =0x11 020005 Title ="Resume Button Maximum" 020011 DescSize =0x5C 020010 Desc ="HRESUM - Higest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E7C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E67 000100 Cat0ID =0x4 020005 Title ="Rev Limit Clear RPM" 020011 DescSize =0x98 020010 Desc ="NLM_CL - Always set lower then the 'Rev Limit Set RPM' (aka NLM_SH) parameter. Fuel delivery remains cut until the engine speed drops below this limit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB086 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1E53 000100 Cat0ID =0x4 020005 Title ="Rev Limit No Fuel" 020011 DescSize =0xA1 020010 Desc ="NLMT - Very harsh limiter, cuts all fuel delivery, always set higher than 'Rev Limit Set RPM' (aka NLM_SH) parameter.\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB098 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4B3E 000100 Cat0ID =0x4 020005 Title ="Rev Limit No Fuel Hysteresis" 020011 DescSize =0x70 020010 Desc ="NLMTH - Hysteresis rpm for 'Rev Limit No Fuel' (aka NLMT) parameter.\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB09A 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2458 000100 Cat0ID =0x4 020005 Title ="Rev Limit Set RPM" 020011 DescSize =0xC1 020010 Desc ="NLM_SH - Always set higher then the 'Rev Limit Clear RPM' (aka NLM_CL) parameter. Fuel delivery remains cut until the engine speed drops below the 'Rev Limit Clear RPM' (aka NLM_CL) parameter." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB084 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x306 000100 Cat0ID =0x5 020005 Title ="RPM Average Time Constant" 020011 DescSize =0xDF 020010 Desc ="TCNDBR - The time constant for the rolling average calculation of the 'RPM Average' (aka NDBAR) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADDC 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7E3A 000100 Cat0ID =0x5 020005 Title ="RPM Time Constant" 020011 DescSize =0xD0 020010 Desc ="TCN - The time constant for the rolling average calculation of the 'RPM' (aka N) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADCC 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5EB8 000100 Cat0ID =0x2 020005 Title ="RPM to MPH Ratio for First Gear" 020011 DescSize =0xEE 020010 Desc ="TTNOV - If the rpm is greater than the result of multiplying the average speed by this parameter then the result of the 'Torque Reduction Table' lookup is subtracted from the final spark advance value.\r\n\r\nMulitplier needs to be confirmed" 020020 Units ="rpm/mph" 020100 Address =0xAA16 020200 Equation =X*4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1FBD 000100 Cat0ID =0x9 020005 Title ="SCVAC Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDTB - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA41A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7989 000100 Cat0ID =0x9 020005 Title ="SCVNT Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDTA - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA418 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1AAC 000100 Cat0ID =0x9 020005 Title ="Self Test Desired RPM" 020011 DescSize =0x6 020010 Desc ="VISCN" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB496 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xDAA 000100 Cat0ID =0x9 020005 Title ="Self Test Ramp Lean Rate" 020011 DescSize =0x7 020010 Desc ="VIPLR1" 020020 Units ="A/F ratio/sec" 020050 SizeInBits =0x10 020100 Address =0xA32A 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x48CD 000100 Cat0ID =0x9 020005 Title ="Self Test Ramp Rich Rate" 020011 DescSize =0x7 020010 Desc ="VIPRR1" 020020 Units ="A/F ratio/sec" 020050 SizeInBits =0x10 020100 Address =0xA328 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x274E 000100 Cat0ID =0x9 020005 Title ="Self Test Ramp Rich Time Delay" 020011 DescSize =0x6 020010 Desc ="VDLY1" 020020 Units ="sec" 020100 Address =0xA43E 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5444 000100 Cat0ID =0x9 020005 Title ="Self Test Set Speed Proportional Gain" 020011 DescSize =0x29 020010 Desc ="VSTGN - Multiplier of 'Set Speed' value." 020020 Units ="dutycycle/mph" 020050 SizeInBits =0x10 020100 Address =0xA442 020150 Flags =0x2 020200 Equation =X/16384,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x20EF 000100 Cat0ID =0x9 020005 Title ="Self Test Vehicle Speed Proportional Gain" 020011 DescSize =0x6 020010 Desc ="VVHGN" 020020 Units ="dutycycle/mph" 020050 SizeInBits =0x10 020100 Address =0xA444 020150 Flags =0x2 020200 Equation =X/16384,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5342 000100 Cat0ID =0x11 020005 Title ="Set Speed Max Increment" 020011 DescSize =0x56 020010 Desc ="ACLDED - The maximum increment above vehicle speed to which 'Set Speed' can increase." 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8E96 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x530F 000100 Cat0ID =0x11 020005 Title ="Set Speed Proportional Gain" 020011 DescSize =0x6 020010 Desc ="SETGN" 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x8E84 020150 Flags =0x2 020200 Equation =X/16384,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5D8C 000100 Cat0ID =0x2 020005 Title ="Signature PIP Difference Value" 020011 DescSize =0xDB 020010 Desc ="MHPFD - Permitted values are;\r\n\r\n8 cylinder, signature dutycycle <= 35% = 0.20\r\n6 cylinder, signature dutycycle <= 30% = 0.24\r\n4 cylinder, signature dutycycle <= 30% = 0.29\r\nSignature PIP distributor not present = 0.99" 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0xB472 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x100A 000100 Cat0ID =0x2 020005 Title ="Signature PIP Half Period Multiplier Filter Constant" 020011 DescSize =0xA 020010 Desc ="FKSKAY - " 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0xA30A 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2CE6 000100 Cat0ID =0x2 020005 Title ="Signature PIP Multiplier Highest Value" 020011 DescSize =0x5B 020010 Desc ="SIGKLU - 1.99996 for 30% dutycycle signature PIP, 1.66666 for 35% dutycycle signature PIP." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0xA30E 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x6181 000100 Cat0ID =0x2 020005 Title ="Signature PIP Multiplier Lowest Value" 020011 DescSize =0x5B 020010 Desc ="SIGKLL - 1.42857 for 30% dutycycle signature PIP, 1.25000 for 35% dutycycle signature PIP." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0xA30C 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x6853 000100 Cat0ID =0x2 020005 Title ="Spark/Fuel Lug Time Limit" 020011 DescSize =0x49 020010 Desc ="LUGTIM - The maximum value that the 'Lugging Timer' (aka LUGTMR) can be." 020020 Units ="secs" 020100 Address =0xAA0D 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B06 000100 Cat0ID =0x2 020005 Title ="Spark Adder for Neutral" 020011 DescSize =0x77 020010 Desc ="NSADD - If in neutral, this is added to the 'CT Spark vs RPM' lookup value when startup kicker adjustment is not used." 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0xAA10 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2AD2 000100 Cat0ID =0x2 020005 Title ="Spark Advance Limit" 020011 DescSize =0x7 020010 Desc ="SPKLIM" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0xAA44 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xC27 000100 Cat0ID =0x2 020005 Title ="Spark Advance Limit PIP%" 020011 DescSize =0x42 020010 Desc ="SPTADV - The percentage of PIP that the spark may be advanced by." 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0xAA22 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4AE6 000100 Cat0ID =0x2 020005 Title ="Spark Interpolation Inhibit" 020011 DescSize =0x139 020010 Desc ="Z_SPKINT - Normally set to \"1E4\", change to \"194\" to eliminate the eec's use of the 'Spark Altitude Table' (aka FN905A) parameter. When using this code modifier the eec will use the 'Spark Sea Level Table' (aka FN904A) regardless of barometric pressure.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="n/a" 020050 SizeInBits =0x10 020100 Address =0x5713 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 020230 RangeLow =-10.0000 020240 RangeHigh =55.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x5D7F 000100 Cat0ID =0x2 020005 Title ="Spark Limit Max" 020011 DescSize =0x7 020010 Desc ="SPUCLP" 020020 Units ="deg adv" 020100 Address =0xAA0B 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4E11 000100 Cat0ID =0x2 020005 Title ="Spark Limit Min" 020011 DescSize =0x7 020010 Desc ="SPLCLP" 020020 Units ="deg adv" 020100 Address =0xAA0A 020200 Equation =X/4,TH|0|0|0|0| 020230 RangeLow =-10.0000 020240 RangeHigh =55.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0xF1A 000100 Cat0ID =0x2 020005 Title ="Spark Max PIP RPM" 020011 DescSize =0x7 020010 Desc ="SPKSWL" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0xAA12 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6591 000100 Cat0ID =0x2 020005 Title ="Spark Min PIP RPM" 020011 DescSize =0x7 020010 Desc ="SPKSWH" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0xAA14 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5482 000100 Cat0ID =0x9 020005 Title ="Spark Test Advance" 020011 DescSize =0x7 020010 Desc ="VIPSPK" 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0xA324 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1EA3 000100 Cat0ID =0x2 020005 Title ="Spark Tip In Advance Per PIP" 020011 DescSize =0x7 020010 Desc ="TIPINC" 020020 Units ="deg adv" 020100 Address =0xAA31 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x45C6 000100 Cat0ID =0x2 020005 Title ="Spark Tip In Max RPM" 020011 DescSize =0x9C 020010 Desc ="NTIP - The maximum rpm allowed in order to a spark tip in condition to be recognised. Must be set to less than 2000 rpm to ensure correct tip in ramp back." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xAA3C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x287 000100 Cat0ID =0x2 020005 Title ="Spark Tip In Min ECT" 020011 DescSize =0x56 020010 Desc ="ECTIP - The minimum ECT allowed in order to a spark tip in condition to be recognised" 020020 Units ="deg F" 020100 Address =0xAA3B 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1681 000100 Cat0ID =0x2 020005 Title ="Spark Tip In Retard" 020011 DescSize =0x3C 020010 Desc ="TIPMAX - The amount of spark retard pulled during a tip in." 020020 Units ="deg adv" 020100 Address =0xAA30 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6538 000100 Cat0ID =0x2 020005 Title ="Spark Tip In TP" 020011 DescSize =0x64 020010 Desc ="KACRAT - The change in throttle position required when closing for a spark tip in to be recognised." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xAA2C 020150 Flags =0x3 020200 Equation =X/6400,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x49AA 000100 Cat0ID =0x4 020005 Title ="Speed Limiter Stage One Off" 020011 DescSize =0xB7 020010 Desc ="HVS_CL - Always set lower then the 'Speed Limiter Stage One On'. AF ratio is enrichened and spark retarded until the engine speed drops below this limit. Set to 127.5 mph to disable." 020020 Units ="mph" 020100 Address =0xB08B 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2507 000100 Cat0ID =0x4 020005 Title ="Speed Limiter Stage One On" 020011 DescSize =0xD8 020010 Desc ="HVS_SH - Speed at which AF ratio is enrichened and spark retarded until the engine speed drops below the 'First Speed Limiter Off'. Always set higher then the 'First Speed Limiter Off'. Set to 127.5 mph to disable." 020020 Units ="mph" 020100 Address =0xB08A 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x12AD 000100 Cat0ID =0x4 020005 Title ="Speed Limiter Stage Two Off" 020011 DescSize =0xAF 020010 Desc ="VVS_CL - Always set lower then the 'Speed Limiter Stage Two On'. Fuel delivery remains cut in half until the engine speed drops below this limit. Set to 127.5 mph to disable." 020020 Units ="mph" 020100 Address =0xB089 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x8B9 000100 Cat0ID =0x4 020005 Title ="Speed Limiter Stage Two On" 020011 DescSize =0x109 020010 Desc ="VVS_SH - Speed at which the injectors are fired alternately to limit speed. Fuel delivery remains cut in half until the engine speed drops below the 'Speed Limiter Stage Two Off'. Always set higher then the 'Second Speed Limiter Off'. Set to 127.5 mph to disable." 020020 Units ="mph" 020100 Address =0xB088 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4EBD 000100 Cat0ID =0x7 020005 Title ="Speed Sensor Present" 020011 DescSize =0x86 020010 Desc ="VSTYPE - \r\n0 = no vehicle speed sensor present\r\n1 = vehicle speed sensor present\r\n2 = vehicle speed sensor and cruise control present" 020020 Units ="none" 020100 Address =0x8EA1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3251 000100 Cat0ID =0x9 020005 Title ="SPOUT Test Min RPM" 020011 DescSize =0x3A 020010 Desc ="VSPRPM - The minimum rpm required to pass the SPOUT test." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA436 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x42C3 000100 Cat0ID =0x9 020005 Title ="SPOUT Test Min Time" 020011 DescSize =0xA1 020010 Desc ="VSPTDL - The minimum time required since the spark advance has been set to the 'SPOUT Test Spark Advance' (aka VSPADV) value before the SPOUT test can continue." 020020 Units ="secs" 020100 Address =0xA43D 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1F50 000100 Cat0ID =0x9 020005 Title ="SPOUT Test Spark Advance" 020011 DescSize =0x7 020010 Desc ="VSPADV" 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0xA438 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7900 000100 Cat0ID =0x9 020005 Title ="SPOUT Test Spark Retard" 020011 DescSize =0x7 020010 Desc ="VSPRET" 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0xA43A 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x278B 000100 Cat0ID =0x5 020005 Title ="Stall RPM" 020011 DescSize =0x37 020010 Desc ="STALLN\r\n\r\nDoes not appear to be used in this strategy." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB46A 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x54A8 000100 Cat0ID =0x1 020005 Title ="Startup Fuel Multiplier" 020011 DescSize =0x1CE 020010 Desc ="NUMPR - A multiplier of the 'CT Neutral Fuel Multiplier vs RPM' (aka FN301N) lookup result used when the following conditions are met;\r\n\r\nThe ECT at startup is between the 'Cold Start Max ECT' (aka CTLOW) and 'Startup Fuel Multiplier Max ECT' (aka CTHIN) parameter values.\r\nThe time since start is less than the 'Startup Fuel Multiplier Time Delay' (aka OLMTD1) parameter value.\r\n\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 020020 Units ="multiplier" 020100 Address =0xA4D5 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xF3E 000100 Cat0ID =0x1 020005 Title ="Startup Fuel Multiplier Max ECT" 020011 DescSize =0x49 020010 Desc ="CTHIN - The maximum ECT at startup to use the 'Startup Fuel Multiplier'." 020020 Units ="deg F" 020100 Address =0xA4D4 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x54A9 000100 Cat0ID =0x1 020005 Title ="Startup Fuel Multiplier Time Delay" 020011 DescSize =0x4C 020010 Desc ="OLMTD1 - The maximum time since start to use the 'Startup Fuel Multiplier'." 020020 Units ="secs" 020100 Address =0xA4D6 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x515A 000100 Cat0ID =0x2 020005 Title ="Startup Kicker Min RPM" 020011 DescSize =0x74 020010 Desc ="HCSD - The minimum rpm for the 'CT Spark Subtractor for BP' table to be used. See also 'Startup Kicker Time Delay'." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xAA04 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x3793 000100 Cat0ID =0x2 020005 Title ="Startup Kicker Min RPM Hysteresis" 020011 DescSize =0x3B 020010 Desc ="HCSDH - Hysteresis for the 'Startup Kicker Min RPM' value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xAA06 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x274D 000100 Cat0ID =0x5 020005 Title ="Steady State Factor" 020011 DescSize =0x36 020010 Desc ="SSFCTR - Used in MKAY and signature KAY calculations." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x8C0A 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x5ADC 000100 Cat0ID =0x7 020005 Title ="Supercharger Bypass Throttle Breakpoint" 020011 DescSize =0xD8 020010 Desc ="THBPSC - Value added to closed throttle value to establish the minimum throttle position at which the supercharger bypass valve is opened. Requires 'Auxillary Hardware Present' (aka THRMHP) parameter to be set to 2." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA310 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3ABE 000100 Cat0ID =0x7 020005 Title ="Supercharger Bypass Throttle Breakpoint Hysteresis" 020011 DescSize =0xDE 020010 Desc ="THBPSH - Value subtracted from combined 'Supercharger Bypass Throttle Breakpoint' and closed throttle value to establish throttle position below which the supercharger bypass valve is closed. Typically set at 0.120 volts." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA312 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B3 000100 Cat0ID =0x7 020005 Title ="Throttle Body Air Flow" 020011 DescSize =0x2F6 020010 Desc ="ITHBMA - This parameter is the air mass flow through the throttle body when the butterfly is closed against the idle stop screw and the ISC dutycycle is 0%. This value is used by the eec to determine the ISC dutycycle required to meet the calculated desired idle air flow. Alter when the throttle body has been changed using this method;\r\n\r\nWith the engine fully warmed up and the idle steady, set the 'Disable ISC' (aka Z_ISCSW) parameter value to \"00\" and hopefully the car will still be idling. Adjust the throttle body stop screw so that the car will just barely idle and set the TPS to ~0.95 volts. Datalog the MAF's flow over a period of 30 seconds and calculate the average. Convert this kg/hr value into lb/min and use this value for this parameter." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA522 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5311 000100 Cat0ID =0x11 020005 Title ="Throttle Position Proportional Gain" 020011 DescSize =0x38 020010 Desc ="TAPGN - A multiplier of the relative throttle position." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x8E88 020150 Flags =0x2 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5818 000100 Cat0ID =0x1 020005 Title ="Time at High Load to Force O/L" 020011 DescSize =0x91 020010 Desc ="HLCTM - The time delay at high load before going to open loop. High load is determined by the 'Load% Min for O/L vs ECT' (aka FN320A) parameter." 020020 Units ="secs" 020100 Address =0xB0A4 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x573F 000100 Cat0ID =0x10 020005 Title ="Time Delay Before N/D or D/N Switch Registers" 020011 DescSize =0xA 020010 Desc ="NDDELT - " 020020 Units ="secs" 020100 Address =0xA55C 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DA1 000100 Cat0ID =0x9 020005 Title ="Time for IDM Bypass After PIP Recovery" 020011 DescSize =0x7 020010 Desc ="VIDMST" 020020 Units ="secs" 020100 Address =0xA34A 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x27C9 000100 Cat0ID =0x9 020005 Title ="Time Out for IDM Fault" 020011 DescSize =0x7 020010 Desc ="VIDMTM" 020020 Units ="mSecs" 020050 SizeInBits =0x10 020100 Address =0xA34C 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x0 %%END%% %%CONSTANT%% 000002 UniqueID =0x155A 000100 Cat0ID =0x3 020005 Title ="TPS Average Closing Time Constant" 020011 DescSize =0x1B1 020010 Desc ="TCDASD - The time constant for the rolling average calculation of the 'TPS Average' (aka DSTPBR) value when the throttle is closing. The 'TPS Average' (aka DSTPBR) value is used in the calculation of the dashpot (pre position airflow) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it. Smaller values reduce the dashpot prior to entry into dashpot control." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADBA 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E6A 000100 Cat0ID =0x3 020005 Title ="TPS Average Opening Time Constant" 020011 DescSize =0x1B3 020010 Desc ="TCDASU - The time constant for the rolling average calculation of the 'TPS Average' (aka DSTPBR) value when the throttle is opening. The 'TPS Average' (aka DSTPBR) value is used in the calculation of the dashpot (pre position airflow) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it. Smaller values result in quicker dashpot response to tip in/out actions." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADBC 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5542 000100 Cat0ID =0x1 020005 Title ="TPS Min Delta for Tip Out" 020011 DescSize =0x9F 020010 Desc ="TPDLTA - The minimum throttle position change required to indicate closing throttle movement. Value must be at least 0.1 volts to avoid A-D conversion jitter." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA4FA 020150 Flags =0xE 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =5.1200 %%END%% %%CONSTANT%% 000002 UniqueID =0x4D89 000100 Cat0ID =0x9 020005 Title ="TPS KOEO Max" 020011 DescSize =0x60 020010 Desc ="VTAP2 - The KOEO test value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA332 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x18E7 000100 Cat0ID =0x9 020005 Title ="TPS KOEO Min" 020011 DescSize =0x61 020010 Desc ="VTAP1 - The KOEO test value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA330 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6898 000100 Cat0ID =0x9 020005 Title ="TPS KOER Max" 020011 DescSize =0x60 020010 Desc ="VTAP4 - The KOER test value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA336 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x301F 000100 Cat0ID =0x9 020005 Title ="TPS KOER Min" 020011 DescSize =0x61 020010 Desc ="VTAP3 - The KOER test value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA334 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3EAB 000100 Cat0ID =0x3 020005 Title ="TPS Knock Strategy Time Constant" 020011 DescSize =0xE5 020010 Desc ="TCTPT - The time constant for the rolling average calculation of the 'TPS Knock Strategy' (aka TBART) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADDE 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x23E3 000100 Cat0ID =0x4 020005 Title ="TPS Max" 020011 DescSize =0x67 020010 Desc ="TAPMAX - The continuous test value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA342 020150 Flags =0xE 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =5.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x497F 000100 Cat0ID =0x9 020005 Title ="TPS Max for Output Test" 020011 DescSize =0x6 020010 Desc ="VTAP5" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA338 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x42E 000100 Cat0ID =0x4 020005 Title ="TPS Min" 020011 DescSize =0x68 020010 Desc ="TAPMIN - The continuous test value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA344 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6B88 000100 Cat0ID =0x9 020005 Title ="TPS Min for Output Test" 020011 DescSize =0x6 020010 Desc ="VTAP6" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA33A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x42E3 000100 Cat0ID =0x3 020005 Title ="TPS O/L Threshold" 020011 DescSize =0xB0 020010 Desc ="THBP5 - The relative throttle position to force open loop.\r\n\r\nNB the relative throttle position is the actual throttle position value minus the closed throttle position value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xB096 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5446 000100 Cat0ID =0x11 020005 Title ="TPS Proportional Gain" 020011 DescSize =0x6 020010 Desc ="VTPGN" 020020 Units ="dutycycle/count" 020050 SizeInBits =0x10 020100 Address =0xA446 020150 Flags =0x2 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7DB3 000100 Cat0ID =0x3 020005 Title ="TPS PT Threshold" 020011 DescSize =0x110 020010 Desc ="DELTA -The relative throttle position at which PT mode occurs. If altered, adjust 'Dashpot TP' (aka DELHYS) and 'ISC RPM Control TP' (aka DELRAT) to suit.\r\n\r\nNB the relative throttle position is the actual throttle position value minus the closed throttle position value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xAD80 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x678F 000100 Cat0ID =0x3 020005 Title ="TPS PT Threshold Hysteresis" 020011 DescSize =0x9D 020010 Desc ="HYSTS - Hysteresis for 'TPS PT Threshold' (aka DELTA) parameter. If altered, adjust 'Dashpot TP' (aka DELHYS) and 'ISC RPM Control TP' (aka DELRAT) to suit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xAD84 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x57D4 000100 Cat0ID =0x3 020005 Title ="TPS Time Constant" 020011 DescSize =0xD5 020010 Desc ="TCTP - The time constant for the rolling average calculation of the 'TPS' (aka TPBAR) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0xADCE 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x791A 000100 Cat0ID =0x3 020005 Title ="TPS WOT Threshold" 020011 DescSize =0xB6 020010 Desc ="THBP2 - The relative throttle position at which WOT mode occurs.\r\n\r\nNB the relative throttle position is the actual throttle position value minus the closed throttle position value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xAD86 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2BCC 000100 Cat0ID =0x3 020005 Title ="TPS WOT Threshold Hysteresis" 020011 DescSize =0x6 020010 Desc ="HYST2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xAD82 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x55A5 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Acceleration Multiplier" 020011 DescSize =0xA5 020010 Desc ="MEFTRA - Multiplier of the transient fuel contribution to the injection pulsewidth.\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 020020 Units ="multiplier" 020100 Address =0xA508 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5572 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Compensation Start Delay" 020011 DescSize =0x5A 020010 Desc ="TFCTM - Time delay from exiting cranking before transient fuel compensation is permitted." 020020 Units ="secs" 020100 Address =0xA504 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x55A7 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Deadband" 020011 DescSize =0xA 020010 Desc ="TFCDED - " 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0xA50A 020150 Flags =0x2 020200 Equation =X/2.56,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x55A6 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Deceleration Multiplier" 020011 DescSize =0xA5 020010 Desc ="MEFTRD - Multiplier of the transient fuel contribution to the injection pulsewidth.\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 020020 Units ="multiplier" 020100 Address =0xA509 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5571 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Max RPM Deadband" 020011 DescSize =0x5F 020010 Desc ="TFSMN - The maximum rpm deadband above idle rpm to disable transient fuel during dashpot mode." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA502 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5570 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Multiplier" 020011 DescSize =0x8E 020010 Desc ="KFT - A global multiplier used in the calculation of the 'Equilbrium Fuel Transfer Rate'. Set to zero to disable transient fuel compensation." 020020 Units ="multiplier" 020100 Address =0xA500 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6EFF 000100 Cat0ID =0x2 020005 Title ="Transient Spark Flag Hi Lo Changes" 020011 DescSize =0x7 020010 Desc ="DFMIN0" 020020 Units ="no." 020100 Address =0xB478 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x33FC 000100 Cat0ID =0x2 020005 Title ="Transient Spark Flag Lo Hi Changes" 020011 DescSize =0x7 020010 Desc ="DFMIN1" 020020 Units ="no." 020100 Address =0xB479 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5888 000100 Cat0ID =0x2 020005 Title ="Transient Spark Min RPM" 020011 DescSize =0x4D 020010 Desc ="TRSRPM - The minimum rpm required to enable the transient spark calculation." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB474 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5D45 000100 Cat0ID =0x2 020005 Title ="Transient Spark Min RPM Hysteresis" 020011 DescSize =0x42 020010 Desc ="TRSRPH - Hysyteresis for the 'Transient Spark Min RPM' parameter." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xB476 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x21AC 000100 Cat0ID =0x10 020005 Title ="Transmission Strategy" 020011 DescSize =0x10A 020010 Desc ="TSTRAT - Selects which transmission strategy to use;\r\n0 = no transmission control\r\n1 = SIL (shift indicator light)\r\n2 = A4LD with 3/4 shift control and convertor clutch control\r\n3 = AXOD\r\n4 = C6E4 (E4OD)\r\n5 = A4LD-E\r\n6 = FAX-4\r\n7 = AOD-4 (AOD-I)\r\n8 = 4EAT\r\n9 = CD4E" 020020 Units ="" 020100 Address =0xB463 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6268 000100 Cat0ID =0x10 020005 Title ="Transmission Type" 020011 DescSize =0x149 020010 Desc ="TRLOAD -\r\n0 = manual, no clutch or gear switches, forced neutral state\r\n1 = manual, no clutch or gear switches\r\n2 = manual, one clutch or gear switch\r\n3 = manual, both clutch and gear switches\r\n4 = auto, non electronic, neutral drive switch\r\n5 = auto, non electronic, neutral pressure switch\r\n6 = auto, electronic, PRNDL sensor" 020020 Units ="" 020100 Address =0xB462 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1811 000100 Cat0ID =0x5 020005 Title ="Underspeed RPM" 020011 DescSize =0x38 020010 Desc ="UNRPM - The rpm below which the UNDERSPEED_FLAG is set." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xAD94 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x51E3 000100 Cat0ID =0x5 020005 Title ="Underspeed RPM Hysteresis" 020011 DescSize =0x3A 020010 Desc ="UNRPMH - The hysteresis value for 'Underspeed RPM' value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xAD96 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x29F2 000100 Cat0ID =0x5 020005 Title ="Unmeasured Air" 020011 DescSize =0x63 020010 Desc ="ARCHLK - Air entering the engine that hasn't been measured by the MAF sensor, e.g. EGR, CANP, PCV." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0xA50C 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5316 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Deadband" 020011 DescSize =0x72 020010 Desc ="MPHDED - If actual mph is less than desired speed minus this value then vehicle speed control should be disabled." 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8E92 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5314 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Disable MPH" 020011 DescSize =0x42 020010 Desc ="MAXVSP - The speed above which vehicle speed control is disabled." 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8E8E 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5315 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Disable RPM" 020011 DescSize =0x40 020010 Desc ="VSNMAX - The rpm above which vehicle speed control is disabled." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8E90 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5344 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Dutycycle Offset" 020011 DescSize =0x7 020010 Desc ="HLDREF" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8E9A 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5313 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Enable MPH" 020011 DescSize =0x3A 020010 Desc ="MINVSP - The minimum mph to enable vehicle speed control." 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8E8C 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5341 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Enable MPH Hysteresis" 020011 DescSize =0x5 020010 Desc ="MPHH" 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8E94 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6259 000100 Cat0ID =0x9 020005 Title ="Vehicle Speed Dutycycle Bias" 020011 DescSize =0x7 020010 Desc ="VDCBIA" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0xA458 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5310 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Proportional Gain" 020011 DescSize =0x4F 020010 Desc ="VEHGN - Multiplier of vehicle speed used in the vehicle speed control routine." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x8E86 020150 Flags =0x2 020200 Equation =X/16384,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5471 000100 Cat0ID =0x9 020005 Title ="Vehicle Speed Ramp Rate" 020011 DescSize =0x6 020010 Desc ="VACRR" 020020 Units ="mph/sec" 020050 SizeInBits =0x10 020100 Address =0xA44C 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5F90 000100 Cat0ID =0x9 020005 Title ="VISDL2" 020011 DescSize =0x32 020010 Desc ="VISDL2\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="secs" 020100 Address =0xB493 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3B3D 000100 Cat0ID =0x5 020005 Title ="Voltage Calibration Constant" 020011 DescSize =0x2A 020010 Desc ="VCAL - Used to calculate battery voltage." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xB08F 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1D9D 000100 Cat0ID =0x9 020005 Title ="VSC Speed Decrease Test Time" 020011 DescSize =0x6 020010 Desc ="VIPT4" 020020 Units ="secs" 020100 Address =0xADE8 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D9D 000100 Cat0ID =0x9 020005 Title ="VSC Speed Post Ramp Test Time Delay" 020011 DescSize =0x7 020010 Desc ="VDLY11" 020020 Units ="secs" 020100 Address =0xA452 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A1A 000100 Cat0ID =0x9 020005 Title ="VSC Speed Ramp Test Time Delay" 020011 DescSize =0x7 020010 Desc ="VDLY10" 020020 Units ="secs" 020100 Address =0xA451 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x76B4 000100 Cat0ID =0x9 020005 Title ="VSC Static Test Max Time" 020011 DescSize =0x6 020010 Desc ="VIPT1" 020020 Units ="secs" 020100 Address =0xA44E 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1181 000100 Cat0ID =0x9 020005 Title ="VSC Test Max Ramp Time" 020011 DescSize =0x6 020010 Desc ="VIPT2" 020020 Units ="secs" 020100 Address =0xA44F 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1D9B 000100 Cat0ID =0x9 020005 Title ="VSC Test Max Time" 020011 DescSize =0x4F 020010 Desc ="VVSCET - The maximum time allowed since power up for the test to be permitted." 020020 Units ="secs" 020100 Address =0xA45A 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7AF6 000100 Cat0ID =0x9 020005 Title ="VSC Test MPH" 020011 DescSize =0x48 020010 Desc ="VMLO - The maximum vehicle speed in order for the test to be permitted." 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0xADE6 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x15FA 000100 Cat0ID =0x9 020005 Title ="VSC Test Set Speed" 020011 DescSize =0x5 020010 Desc ="VRSS" 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0xA44A 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2322 000100 Cat0ID =0x9 020005 Title ="VSC Test Set Speed Hysteresis" 020011 DescSize =0x5 020010 Desc ="VRSH" 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0xA448 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x761D 000100 Cat0ID =0x9 020005 Title ="VSC Test TP Min Change" 020011 DescSize =0x6 020010 Desc ="VTPLD" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA454 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3730 000100 Cat0ID =0x9 020005 Title ="VSC Test TP Max Change" 020011 DescSize =0x6 020010 Desc ="VTPLU" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0xA456 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52B1 000100 Cat0ID =0x11 020005 Title ="VSCCS Min Change" 020011 DescSize =0xB7 020010 Desc ="DEBAMP - The minimum change in voltage of the Vehicle Speed Control Command Switch for the 'Debounce Timer' (aka DEBTMR) to be reset to the 'Debounce Time Delay' (aka DEBTIM) value. " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E6C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x77A9 000100 Cat0ID =0x11 020005 Title ="VSS Error Deadband" 020011 DescSize =0x48 020010 Desc ="HLDRNG - VSC dutycycle error deadband for which no pulses are required." 020020 Units ="%" 020100 Address =0xA31A 020200 Equation =X/128,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x39DB 000100 Cat0ID =0x7 020005 Title ="VSS Frequency" 020011 DescSize =0x7 020010 Desc ="VSCFRQ" 020020 Units ="Hz" 020100 Address =0x8EA0 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2B5D 000100 Cat0ID =0x9 020005 Title ="VSS Test Decel MAP Max" 020011 DescSize =0x1E 020010 Desc ="VSMAPL - Manual gearbox only." 020020 Units ="in Hg" 020100 Address =0xA45B 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5216 000100 Cat0ID =0x9 020005 Title ="VSS Test Min MPH" 020011 DescSize =0x7 020010 Desc ="VSSMN1" 020020 Units ="mph" 020100 Address =0xA460 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4DDF 000100 Cat0ID =0x9 020005 Title ="VSS Test Min Time" 020011 DescSize =0x45 020010 Desc ="VSSTIM - The minimum time required before the VSS test can continue." 020020 Units ="secs" 020100 Address =0xA462 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4911 000100 Cat0ID =0x9 020005 Title ="VSS Test Min RPM Auto Gearbox" 020011 DescSize =0xA 020010 Desc ="VSAMIN - " 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA45C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x339F 000100 Cat0ID =0x9 020005 Title ="VSS Test Min RPM Manual Gearbox" 020011 DescSize =0xA 020010 Desc ="VSMMIN - " 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0xA45E 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7F75 000100 Cat0ID =0x1 020005 Title ="Warm HEGO Flag Cold Start Delay #1" 020011 DescSize =0x130 020010 Desc ="OPCLT1 - When the ECT at start is less than the 'Cold Start Max ECT' value this is the minimum time that must pass since exiting crank in order for the WARM_EGO_FLAG to be set.\r\n\r\nNote: the 'HEGO Min Switches Before Warm' (aka EGOCL1) and 'Warm HEGO Flag Cold Start Delay #2' values also need exceeding." 020020 Units ="secs" 020100 Address =0xB093 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2B7D 000100 Cat0ID =0x1 020005 Title ="Warm HEGO Flag Cold Start Delay #2" 020011 DescSize =0x14E 020010 Desc ="OPCLT4 - When the ECTat start is less than the 'Cold Start Max ECT' value this is the minimum time that must pass since the ECT exceeded the 'Engine Warm ECT' value in order for the WARM_EGO_FLAG to be set.\r\n\r\nNote: the 'HEGO Min Switches Before Warm' (aka EGOCL1) and 'Warm HEGO Flag Cold Start Delay #1' values also need exceeding." 020020 Units ="secs" 020100 Address =0xB094 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6872 000100 Cat0ID =0x1 000101 Cat1ID =0xB 020005 Title ="Warm HEGO Flag Hot Start Delay" 020011 DescSize =0x162 020010 Desc ="OPCLT3 - When the ECT at start is greater than the 'Hot Start Min ECT' value this is the minimum time that must pass since exiting crank in order for the WARM_EGO_FLAG to be set.\r\n\r\nNote: the 'HEGO Min Switches Before Warm' (aka EGOCL1) value also needs exceeding.\r\n\r\nThis parameter is also used during failure management when the ECT sensor has failed." 020020 Units ="secs" 020100 Address =0xB090 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4B61 000100 Cat0ID =0x1 000101 Cat1ID =0xB 020005 Title ="Warm HEGO Flag Warm Start Delay #1" 020011 DescSize =0x1A0 020010 Desc ="OPCLT2 - When the ECT at start is between the 'Cold Start Max ECT' and 'Hot Start Min ECT' values this is the minimum time that must pass since exiting crank in order for the WARM_EGO_FLAG to be set.\r\n\r\nNote: the 'HEGO Min Switches Before Warm' (aka EGOCL1) and 'Warm HEGO Flag Warm Start Delay #2' values also need exceeding.\r\n\r\nThis parameter is also used during failure management when the ECT sensor has failed." 020020 Units ="secs" 020100 Address =0xB091 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1166 000100 Cat0ID =0x1 020005 Title ="Warm HEGO Flag Warm Start Delay #2" 020011 DescSize =0x166 020010 Desc ="OPCLT5 - When the ECT at start is between the 'Cold Start Max ECT' and 'Hot Start Min ECT' values this is the minimum time that must pass since the ECT exceeded the 'Engine Warm ECT' value in order for the WARM_EGO_FLAG to be set.\r\n\r\nNote: the 'HEGO Min Switches Before Warm' (aka EGOCL1) and 'Warm HEGO Flag Warm Start Delay #1' values also need exceeding." 020020 Units ="secs" 020100 Address =0xB092 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x42FA 000100 Cat0ID =0x9 020005 Title ="Wiggle Test Upcount Threshold" 020011 DescSize =0x7 020010 Desc ="WIGLVL" 020020 Units ="" 020100 Address =0xA346 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5CD2 000100 Cat0ID =0x2 020005 Title ="WOT Spark Adder" 020011 DescSize =0x5 020010 Desc ="KWS1" 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0xAA08 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x43E4 000100 Cat0ID =0x2 020005 Title ="WOT Spark Elimination" 020011 DescSize =0x2CE 020010 Desc ="Z_WSPKSW - This is normally set to \"D030\", change to \"4920\" to use the part throttle spark parameters instead of the WOT spark parameters when at WOT.\r\n\r\nWARNING: Do not use any values other than these OR attempt to make this change whilst emulating.\r\n\r\nOptionable: Next use the Hex Editor (ctrl + H) to fill the addresses from 0x56A3 to 0x56EB with \"FF\". WARNING: These changes are non reversable.\r\n\r\nThe following parameters are now ineffective and any alterations made to them will not have any effect on the spark timing;\r\n\r\n'WOT Spark Adder' (aka KWS1) \r\n'WOT Spark Advance vs ACT' (aka FN135)\r\n'WOT Spark Advance vs BP' (aka FN133)\r\n'WOT Spark Advance vs ECT' (aka FN134)\r\n'WOT Spark Advance vs RPM' (aka FN131)" 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x56A1 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%TABLE%% 000002 UniqueID =0x64CB 000100 Cat0ID =0x7 040005 Title ="Injector Output Port" 040011 DescSize =0x113 040010 Desc ="FN1327 - Links the injector to a calculated fuel pulsewidth.\r\n\r\n1 = use Fuel Pulsewidth #1\r\n2 = use Fuel Pulsewidth #2.\r\n\r\nNote: If the 'Number of HEGOs' (aka NUMEGO) parameter = 1 then set all entries to 1 or cylinder bank 2 will receive no fuel. Only use values of 1 or 2." 040100 Address =0xA6A5 040200 ZEq =X/2+1,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040205 OutType =0x2 040210 DecimalPl =0x1 040230 RangeLow =0.0000 040240 RangeHigh =10.0000 040300 Rows =0x1 040305 Cols =0x8 040320 XUnits ="Injector Port" 040325 YUnits ="n/a" 040330 ZUnits ="no." 040350 XLabels =1,2,3,4,5,6,7,8 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =Port 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6499 000100 Cat0ID =0x7 040005 Title ="Injector Timing" 040011 DescSize =0x278 040010 Desc ="FN1315 - Defines the injector firing timing point from TDC. Can indicate the start or end timing point of the injector pulse depending on the setting of the 'Injector Timing Edge' (aka INJREF) parameter. The result from is table lookup is modified by the 'Injector Timing Multiplier' (aka IDKMUL) and 'Injector Timing Delay' (aka IDKADD) parameters.\r\n\r\nIf the appropriate conditions are met then a fixed injector timing value may alternatively be provided by one of the following parameters;\r\n\r\n'Injector Timing Value at Idle' (aka MIDTV)\r\n'Injector Timing Value for MFA' (aka MINTV)\r\n'Injector Timing Value in Neutral' (aka CINTV)" 040100 Address =0xA654 040200 ZEq =X*4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040205 OutType =0x2 040210 DecimalPl =0x1 040230 RangeLow =0.0000 040240 RangeHigh =1000.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="crank deg" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0xDA3 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xDA3 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Injector Timing Scaler for Load" 040011 DescSize =0x7B 040010 Desc ="FN085 - Do not edit first or last entries. Provides row scaling for the following table;\r\n\r\n'Injector Timing' (aka FN1315)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="load" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =Load,Table Row Index 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0xA63C 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA63E 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1655 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC Adder vs RPM" 040011 DescSize =0xFC 040010 Desc ="FN810 - An adder used in the calculation of the desired ISC valve airflow to correct for dips in the idle rpm. If the base target idle speed values have been altered then adjust the input rpm in rows 2, 3 and 4 to suit. Do not edit first or last rows." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels =Speed 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4096,TH|0|0|0|0| 040600 XAddress =0xA77A 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA77C 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x648E 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC C/L RPM Correction Rate" 040011 DescSize =0x6 040010 Desc ="FN860" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="rate" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040600 XAddress =0xA862 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA864 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7454 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC Dutycycle During Crank" 040011 DescSize =0x6 040010 Desc ="FN884" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="deg F at start" 040325 YUnits ="dutycycle" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/1.28,TH|0|0|0|0| 040600 XAddress =0xA8EA 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA8EB 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xCB5 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC Dutycycle Multiplier vs Load" 040011 DescSize =0xBB 040010 Desc ="FN820B - Used to compensate for the increase in airflow through the ISC valve during high manifold vacuum compared to normal idle vacuum levels, e.g. during closed throttle deceleration." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="load" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Time in Crank Mode,Crank Fuel Multiplier 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xA7EE 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA7F0 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x54D3 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC Gain vs RPM Error" 040011 DescSize =0x289 040010 Desc ="FN824 - A multplier of the following parameters, used as input in IPSIBR calculation for proportion correction of idle rpm when in closed loop rpm control. The input rpm at rows 4 and 5 should typically be set to 16 rpm lower and higher respectively than the base target idle speed value. The input rpm at rows 3 and 6 should typically be set to approximately 200 rpm lower and higher respectively than the base target idle speed value. Do not edit the first or last rows.\r\n\r\nISC Gain For Overspeed in Drive (to be confirmed)\r\nISC Gain For Overspeed in Neutral\r\nISC Gain For Underspeed in Drive (to be confirmed)\r\nISC Gain For Underspeed in Neutral" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="gain" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/64,TH|0|0|0|0| 040600 XAddress =0xA806 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA807 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xE7D 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="ISC Startup Scaler for ECT" 040011 DescSize =0x7D 040010 Desc ="FN020C - Do not edit first or last entries. Provides column scaling for the following table;\r\n\r\n'Desired Airflow Multiplier'" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =ECT,Table Index 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0xA740 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA741 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x10B5 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="ISC Time Scaler for Time" 040011 DescSize =0x7B 040010 Desc ="FN018B - Do not edit first or last entries. Provides row scaling for the following table;\r\n\r\n'Desired Airflow Multiplier'" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="secs" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =Table Index 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xB100 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB102 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2142 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC Transfer" 040011 DescSize =0x4F 040010 Desc ="FN800 - Alter if air flow characteristics through the ISC valve have changed." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xC 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="dutycycle" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4096,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/327.68,TH|0|0|0|0| 040600 XAddress =0xA74A 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA74C 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xE68 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Knock Advance Rate vs RPM" 040011 DescSize =0x1D6 040010 Desc ="FN146B - This limits the rate at which the spark returns to the calculated spark advance following retardation due to knock control in order to avoid pinging. This value is the number of milliseconds that must pass since the last spark increment before the next increment is allowed to occur. Decrease to improve throttle response. When allowed, the spark is advanced a 1/4 of a degree each time at a maximum rate of a 1/4 quarter of a degree between each firing event." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="mSecs" 040330 ZUnits ="" 040350 XLabels =RPM,Seconds/Degree 040352 XLabelType =0x4 040354 XEq =X/4*128,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0xAD6A 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAD6B 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6C27 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Knock Retard Increment vs RPM" 040011 DescSize =0x7 040010 Desc ="FN143A" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="sec/degrees" 040330 ZUnits ="" 040350 XLabels =Speed,Y 040352 XLabelType =0x4 040354 XEq =X/4*128,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0xAD46 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAD47 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4DFC 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Knock Threshold Window Time" 040011 DescSize =0xA 040010 Desc ="FN144A - " 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="PIP period fraction" 040330 ZUnits ="" 040350 XLabels =Speed,Y 040352 XLabelType =0x4 040354 XEq =X*32,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/1024,TH|0|0|0|0| 040600 XAddress =0xAD52 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAD53 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2B30 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Knock Threshold Window Position" 040011 DescSize =0x72 040010 Desc ="FN145A - The result of this lookup is added to the 'Knock Threshold Window Position Delay' (aka WOPEN) parameter." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="PIP period fraction" 040330 ZUnits ="" 040350 XLabels =Speed 040352 XLabelType =0x4 040354 XEq =X/4*128,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xAD60 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAD61 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x6 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xBE5 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Load% Min for O/L vs ECT" 040011 DescSize =0x17B 040010 Desc ="FN320A - Use to set the minimum load% required to permit entry into open loop operation according to ECT.\r\n\r\nWhen the result of this table's lookup is less than LOAD% then the 'Inhibit High Load Timer Flag' is set. If the 'Inhibit High Load Timer Flag' is clear then open loop mode is entered after the 'Time at High Load to Force O/L' (aka HLCTM) time period has been exceeded." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="load%" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/327.68,TH|0|0|0|0| 040600 XAddress =0xB2B0 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB2B2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x461 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="LOM Table" 040011 DescSize =0x65 040010 Desc ="FN125 - Used to determine if the more aggressive 'Spark Base Table' (aka FN901) table is to be used." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="" 040350 XLabels =Speed 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/327.68,TH|0|0|0|0| 040600 XAddress =0xAAA8 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAAAA 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x429B 000100 Cat0ID =0x3 040005 Title ="MAF Backflow Correction" 040011 DescSize =0x52 040010 Desc ="FN1035 - Multiplier of raw air mass to compensate for backflow in the MAF sensor." 040100 Address =0xB1A4 040200 ZEq =X/128,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =8.0000 040240 RangeHigh =18.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="A/F Ratio" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x5130 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2748 000100 Cat0ID =0x3 000101 Cat1ID =0xFF 040005 Title ="MAF Transfer" 040011 DescSize =0x3A 040010 Desc ="FN036 - Output is shown in kg/hr (converted from lb/tick)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x1E 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="kg/hr" 040330 ZUnits ="" 040350 XLabels =MAF Voltage,Mass Flow 040352 XLabelType =0x4 040354 XEq =X/4096,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =x/7.407407407,TH|0|0|0|0| 040600 XAddress =0xA274 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA276 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xFEA 000100 Cat0ID =0xF 000101 Cat1ID =0xFF 040005 Title ="MFA Altitude Multiplier vs BP" 040011 DescSize =0x3F 040010 Desc ="FN311 - Also used in part throttle spark and EGR calculations." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xA5AD 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA5AE 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2D8C 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="MFA EGR and PT Spark Scaler for Load " 040011 DescSize =0xA2 040010 Desc ="FN082 - Do not edit first or last entries. Provides row scaling for the following tables;\r\n\r\n'MFA EGR Multiplier' (aka FN1223)\r\n'MFA PT Spark Adder' (aka FN1124)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="load" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xA194 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA196 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xA15 000100 Cat0ID =0xF 040005 Title ="MFA EGR Multiplier" 040011 DescSize =0x45 040010 Desc ="FN1223 - Multiplier used for ramping in managed fuel air EGR tables." 040100 Address =0xB02A 040200 ZEq =X/128,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x3 040305 Cols =0x4 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="multiplier" 040350 XLabels = 500, 700, 900, 1100 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3987 040505 XLabelSource =0x2 040510 YLabelLink =0x2D8C 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3AAD 000100 Cat0ID =0xF 040005 Title ="MFA Fuel Multiplier Table" 040011 DescSize =0xFA 040010 Desc ="FN1328 - Open loop mode multiplier that adjusts the desired A/F ratio when the conditions for economy mode are met and the 'Allow MFA Strategy' (aka MFASW) flag is set.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040100 Address =0xA55D 040200 ZEq =X/128,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load%" 040330 ZUnits ="multiplier" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.08,0.15,0.27,0.40,0.55,0.70,0.80,0.90 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x6012 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6561 000100 Cat0ID =0x2 040005 Title ="MFA PT Spark Adder" 040011 DescSize =0xA 040010 Desc ="FN1124 - " 040100 Address =0xAC82 040150 Flags =0x1 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =100.0000 040300 Rows =0x3 040305 Cols =0x4 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="" 040350 XLabels = 900,1267,1633,2000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.18,0.29,0.52 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3987 040505 XLabelSource =0x2 040510 YLabelLink =0x2D8C 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x22C5 000100 Cat0ID =0x5 000101 Cat1ID =0xFF 040005 Title ="Peak Load at Sea Level vs RPM" 040011 DescSize =0x13B 040010 Desc ="FN035 - Used in the calculation of load% when the 'Percent Load Switch' (aka PRLDSW) parameter is not set. Adjust when the volumetric efficiency of the engine has changed. The values in the output column are the maximum peak load for a given RPM when at sea level and the inlet air charge temperature is 100 deg F." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/327.68,TH|0|0|0|0| 040600 XAddress =0xB294 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB296 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x653B 000100 Cat0ID =0x2 040005 Title ="PT Spark Adder for ECT vs Load" 040011 DescSize =0xA 040010 Desc ="FN1133 - " 040100 Address =0xACDE 040150 Flags =0x1 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =-50.0000 040240 RangeHigh =50.0000 040300 Rows =0x8 040305 Cols =0x7 040320 XUnits ="deg F" 040325 YUnits ="load" 040330 ZUnits ="" 040350 XLabels = 60, 75, 91,106,196,210,230 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3658 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6532 000100 Cat0ID =0x2 040005 Title ="PT Spark Adder for EGR" 040011 DescSize =0x9B 040010 Desc ="FN1121 - The result of this table lookup is multiplied by the 'Actual EGR Percent' (aka EGRACT) value to give a spark adder value whilst at part throttle." 040100 Address =0xAC32 040150 Flags =0x1 040200 ZEq =X/64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="multiplier" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4CF3 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="PT Spark Adder for ACT" 040011 DescSize =0x6 040010 Desc ="FN126" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0xC0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Air Charge Temperature,Spark Advance [deg adv] 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0xAABC 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAABD 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3658 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="PT Spark Scaler for ECT" 040011 DescSize =0x8E 040010 Desc ="FN033 - Do not edit first or last entries. Provides column scaling for the following table;\r\n\r\n'PT Spark Adder for ECT and Load' (aka FN1133)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x9 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =ECT,Table Index 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xAA56 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAA58 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x49E7 000100 Cat0ID =0x5 000101 Cat1ID =0xFF 040005 Title ="Sea Level Multiplier vs BP" 040011 DescSize =0x13E 040010 Desc ="FN212A - Used in sea level spark, open loop fuel and EGR calculations. Should be set to 0.000 at high altitudes and 1.000 at sea level. Values must overlap with the 'Altitude Multiplier vs BP' (aka FN129A) table. \r\n\r\nFor EGR, this is a multiplier of the result of the 'EGR Sea Level Table' (aka FN908A) table lookup." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0xAECA 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAECB 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xBF0 000100 Cat0ID =0x2 040005 Title ="Spark Altitude Table" 040011 DescSize =0x180 040010 Desc ="FN905A - The result of this table lookup is multiplied by the result of the 'Altitude Multiplier vs BP' (aka FN129A) lookup. This is part of the ecu's interpolation between the 'Spark Altitude Table' and the 'Spark Sea Level Table' (aka FN904A) during normal part throttle operation. \r\n\r\nTo eliminate this interpolation use the 'Spark Interpolation Inhibit' (aka Z_SPKINT) parameter." 040100 Address =0xABE2 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =60.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="deg adv" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4775 000100 Cat0ID =0x2 040005 Title ="Spark Base Table" 040011 DescSize =0x42 040010 Desc ="FN901 - A more aggressive spark advance used during acceleration." 040100 Address =0xAB42 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =60.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="deg adv" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1425 000100 Cat0ID =0x2 040005 Title ="Spark Sea Level Table" 040011 DescSize =0x181 040010 Desc ="FN904A - The result of this table lookup is multiplied by the result of the 'Sea Level Multiplier vs BP' (aka FN212A) lookup. This is part of the ecu's interpolation between the 'Spark Sea Level Table' and the 'Spark Altitude Table' (aka FN905A) during normal part throttle operation. \r\n\r\nTo eliminate this interpolation use the 'Spark Interpolation Inhibit' (aka Z_SPKINT) parameter." 040100 Address =0xAB92 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =60.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="deg adv" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7CE5 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Spark, Injector Timing, MAF Backflow Scaler for RPM" 040011 DescSize =0x187 040010 Desc ="FN070 - Do not edit first or last entries. Provides column scaling for the following tables;\r\n\r\n'Adaptive Control Learning Table'\r\n'EGR Altitude Table'\r\n'EGR Sea Level Table'\r\n'Failed Mass Air Flow Sensor'\r\n'Injector Timing'\r\n'MAF Backflow Correction'\r\n'MFA Fuel Table'\r\n'PT Spark Adder for EGR'\r\n'Spark Altitude Table'\r\n'Spark Base Table'\r\n'Spark Sea Level Table'\r\n'Torque Reduction Table'" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =Speed,Table Column (X) Index 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xA140 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA142 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4826 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Startup Kicker Time Delay" 040011 DescSize =0xC8 040010 Desc ="FN400 - If the time since exiting crank is greater that the result of this lookup, and the rpm is greater than the 'Startup Kicker Min RPM' value, then 'CT Spark Subtractor for BP' table is not used." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="deg F at start" 040325 YUnits ="secs" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040600 XAddress =0xAB36 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAB37 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x31B9 000100 Cat0ID =0x2 040005 Title ="Torque Reduction Table" 040011 DescSize =0x7 040010 Desc ="FN1119" 040100 Address =0xAC8E 040150 Flags =0x1 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="deg adv" 040350 XLabels =(null),(null),(null),(null),(null),(null),(null),(null),(null),(null) 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =(null),(null),(null),(null),(null),(null),(null),(null) 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x29C8 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="TP Scaler for MAF Failure" 040011 DescSize =0xB5 040010 Desc ="FN098 - Do not edit first or last entries. Provides row scaling for the following table using the relative throttle position as the input value;\r\n\r\n'Failed MAF Sensor' (aka FN1358)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/12800,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0xA5BA 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xA5BC 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2608 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Underspeed Fuel Multiplier" 040011 DescSize =0xB7 040010 Desc ="FN387 - A multiplier of the 'Decel Fuel Shut Off Multiplier' lookup value when in underspeed mode.\r\nMultiplier values less than 1 decrease fuel, values greater than 1 increase fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x9 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="muliplier" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/64,TH|0|0|0|0| 040600 XAddress =0xAE7A 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAE7B 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1FD0 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="WOT Fuel Multiplier vs RPM" 040011 DescSize =0x84 040010 Desc ="FN303 - Adjusts the desired A/F ratio when at WOT.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =RPM,WOT Fuel Multiplier 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x2B184 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xB186 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x421A 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="WOT Spark Advance vs ACT" 040011 DescSize =0x55 040010 Desc ="FN135 - Spark advance added to 'WOT Spark Advance vs RPM' (aka FN131) lookup result." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0xC0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Intake Air Charge Temp,WOT Spark Advance 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0xAB0E 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAB0F 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2660 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="WOT Spark Advance vs BP" 040011 DescSize =0x56 040010 Desc ="FN133 - Spark advance added to 'WOT Spark Advance vs RPM' (aka FN131) lookup result." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x80 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure,Spark Adder 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0xAAF6 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAAF7 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x38D4 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="WOT Spark Advance vs ECT" 040011 DescSize =0x56 040010 Desc ="FN134 - Spark advance added to 'WOT Spark Advance vs RPM' (aka FN131) lookup result." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0xC0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Engine Coolant Temp,WOT SparkAdvance 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0xAB00 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAB01 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6F6E 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="WOT Spark Advance vs RPM" 040011 DescSize =0x23 040010 Desc ="FN131 - Spark advance used at WOT." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x380 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x9 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =RPM,WOT Spark Advance 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0xAAD2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0xAAD4 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%FLAG%% 000002 UniqueID =0x66FC 000100 Cat0ID =0x1 030005 Title ="Allow Accel Enrichment" 030011 DescSize =0x5A 030010 Desc ="AEFLAG - Set to allow acceleration enrichment.\r\n\r\nDoes not appear to be used in this ecu." 030100 Address =0xA4F8 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x178B 000100 Cat0ID =0x9 030005 Title ="Allow Brake On/Off Test" 030011 DescSize =0x1B 030010 Desc ="VBISW - Set to permit test" 030100 Address =0xA368 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3581 000100 Cat0ID =0xB 030005 Title ="Allow C/L Re-entry on HEGO Failure" 030011 DescSize =0x57 030010 Desc ="LOESSW - Set to permit re-entry into closed loop fuelling when EGOs are not switching." 030100 Address =0xA934 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x71BC 000100 Cat0ID =0xC 030005 Title ="Allow EPT at Idle" 030011 DescSize =0x49 030010 Desc ="EPTSW - Set to permit the 'EPT at Idle' (EPTZER) value to be calculated." 030100 Address =0xADB0 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x1E50 000100 Cat0ID =0x9 030005 Title ="Allow Fuel Pump Monitor Test" 030011 DescSize =0x45 030010 Desc ="V_FPMFLG - Set to permit the Fuel Pump Monitor Test to be performed." 030100 Address =0xA347 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x951 000100 Cat0ID =0x9 030005 Title ="Allow Goose Test" 030011 DescSize =0x1D 030010 Desc ="V_GOOSW - Set to permit test" 030100 Address =0xA362 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x37C1 000100 Cat0ID =0x9 030005 Title ="Allow HEGO Switch Test" 030011 DescSize =0x1C 030010 Desc ="VEGOBP - Set to permit test" 030100 Address =0xA37A 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3B7C 000100 Cat0ID =0xF 030005 Title ="Allow MFA Strategy" 030011 DescSize =0x37 030010 Desc ="MFASW - Set for fuel economy mode strategy to be used." 030100 Address =0xA4D1 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x1F48 000100 Cat0ID =0xD 030005 Title ="Allow O/L Canister Purge" 030011 DescSize =0x38 030010 Desc ="PURGSW - Set to permit canister purge during open loop." 030100 Address =0xA943 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0xBA9 000100 Cat0ID =0x9 030005 Title ="Allow Power Steering Test" 030011 DescSize =0x45 030010 Desc ="VPSSW - Set to permit testing of the power steering pressure switch." 030100 Address =0xA434 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3F38 000100 Cat0ID =0x9 030005 Title ="Allow Secondary Air Test" 030011 DescSize =0x7 030010 Desc ="VAIRFL" 030100 Address =0xA321 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x57DA 000100 Cat0ID =0x9 030005 Title ="Allow SPOUT Test" 030011 DescSize =0x1C 030010 Desc ="VSPTEN - Set to permit test" 030100 Address =0xA43C 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x5C7C 000100 Cat0ID =0x9 030005 Title ="Allow Thermactor Test" 030011 DescSize =0x7 030010 Desc ="VTABFL" 030100 Address =0xA322 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x1C7 000100 Cat0ID =0x9 030005 Title ="Allow VSS Test" 030011 DescSize =0x1B 030010 Desc ="VSSSW - Set to permit test" 030100 Address =0xA461 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0xC49 000100 Cat0ID =0xE 030005 Title ="Alternator Control Present" 030011 DescSize =0x121 030010 Desc ="ECADHP - Set if an Electronically Controlled Accessory Drive (ECAD) module is present. This module monitors alternator demand and signals the eec when demand is low. If the appropriate conditions are met then the eec signals the ECAD module that the alternator is to be run at half speed." 030100 Address =0xA935 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3AE7 000100 Cat0ID =0x3 030005 Title ="BAP Sensor Present" 030011 DescSize =0x37 030010 Desc ="BPSSW - Set if a Barometric Pressure Sensor is fitted." 030100 Address =0xAA49 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x73B4 000100 Cat0ID =0x7 030005 Title ="Brake Switch Present" 030011 DescSize =0x2A 030010 Desc ="BIHP - Set if brake pedal switch present." 030100 Address =0xA90F 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x764B 000100 Cat0ID =0x9 030005 Title ="Bypass Fault Reporting" 030011 DescSize =0x57 030010 Desc ="VDISFM - Set to inhibit fault reporting. Not sure which fault reporting this prevents." 030100 Address =0xA364 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x5997 000100 Cat0ID =0x7 030005 Title ="CID Sensor Present" 030011 DescSize =0x57 030010 Desc ="HP_CID - Set if cylinder identification hardware present, e.g. for an EDIS conversion." 030100 Address =0xB470 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x48C 000100 Cat0ID =0x7 030005 Title ="CID Sensor Type" 030011 DescSize =0x6D 030010 Desc ="HP_CIDSEL - set for Variable Reluctance sensor, clear for a Hall Effect sensor. Used for an EDIS conversion." 030100 Address =0xB471 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x78EC 000100 Cat0ID =0x2 030005 Title ="Computer Controlled Dwell Present" 030011 DescSize =0x89 030010 Desc ="CCDSW - Set if dwell is computer controlled and a \"black\" CCD TFI module is used otherwise dwell is TFI controlled with a \"gray\" module." 030100 Address =0xAA18 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x6B55 000100 Cat0ID =0x1 030005 Title ="Crank Injector Timing" 030011 DescSize =0x76 030010 Desc ="EDSEL - Set to use the rising edge of the PIP for injector firing during cranking otherwise the falling edge is used." 030100 Address =0xB0B6 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x5F49 000100 Cat0ID =0x1 030005 Title ="Decel Fuel Shut Off PT Enable" 030011 DescSize =0x9B 030010 Desc ="PTDFSW - Set for PT deceleration fuel shut off, clear for CT deceleration fuel shut off. It is not advisable to set this as it can cause engine 'clunk'. " 030100 Address =0xB0E5 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x2371 000100 Cat0ID =0x7 030005 Title ="Electro Drive Fan Present" 030011 DescSize =0x30 030010 Desc ="EDFHP - Set if an electro drive fan is present." 030100 Address =0xA96A 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3750 000100 Cat0ID =0x7 030005 Title ="Enable Special Injector Timing at Idle" 030011 DescSize =0x7F 030010 Desc ="CIDRSW - Set to fix the injector timing to the 'Injector Timing Value at Idle' (aka MIDTV) value when the vehicle is in drive." 030100 Address =0xB0C0 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x5328 000100 Cat0ID =0x7 030005 Title ="Enable Special Injector Timing in Neutral" 030011 DescSize =0x65 030010 Desc ="CINTSW - Set to fix the injector timing to the 'Injector Timing Value in Neutral' (aka CINTV) value." 030100 Address =0xA4D2 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x7EB2 000100 Cat0ID =0x1 030005 Title ="Force Background Fuel" 030011 DescSize =0x40 030010 Desc ="BFULSW - Set to prevent foreground fuel pulsewidth calculation." 030100 Address =0xA308 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x4F26 000100 Cat0ID =0x2 030005 Title ="High Data Rate Electronic Spark Present" 030011 DescSize =0x29 030010 Desc ="HP_HIDRES - Used for an EDIS conversion." 030100 Address =0xAA18 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x1E31 000100 Cat0ID =0x7 030005 Title ="High Speed Fan Present" 030011 DescSize =0x3B 030010 Desc ="HEDFHP - Set if the electro drive fan is a two speed unit." 030100 Address =0xA96B 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x2814 000100 Cat0ID =0x7 030005 Title ="Injector Timing Edge" 030011 DescSize =0x79 030010 Desc ="INJREF - Indicates which edge of the fuel pulse is used for the injector timing, clear = rising edge, set = falling edge" 030100 Address =0xA4EE 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x4FAD 000100 Cat0ID =0x2 030005 Title ="Knock Sensor Present" 030011 DescSize =0x29 030010 Desc ="KIHP - Set if a knock sensor is present." 030100 Address =0xAA48 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x6D31 000100 Cat0ID =0x1 030005 Title ="Lambda Reset Switch" 030011 DescSize =0x6E 030010 Desc ="LAMSW - Set if desired A/F ratio is to be clipped to be no leaner than 14.64 when transiting from O/L to C/L." 030100 Address =0xB46C 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3947 000100 Cat0ID =0x2 030005 Title ="Lugging Timer Reset Switch" 030011 DescSize =0x90 030010 Desc ="LUGSW - If set then the 'Lugging Timer' (aka LUGTMR) is cleared before the Lugging Timer Up Flag is cleared and Lugging Timer Down Flag is set." 030100 Address =0xAA0E 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x70DC 000100 Cat0ID =0x5 030005 Title ="Percent Load Switch" 030011 DescSize =0x22A 030010 Desc ="PRLDSW - Used for determining the value of load%.\r\n\r\nSet for load% = load\r\nClear for load% = load/peak load\r\n\r\nIf this parameter is altered then the following parameters will/may need adjusting to suit;\r\n\r\n'Fuel Lugging Mode O/L Min Load%' (aka LDMH)\r\n'Fuel Lugging Mode O/L Min Load% Hysteresis' (aka LDMHH)\r\n'Fuel Scaler for Load%' (aka FN072A)\r\n'Load% Min for O/L Hysteresis' (aka HLODH)\r\n'Load% Min for O/L vs ECT' (aka FN320A)\r\n'Thermactor Upstream Air Timer Min Load%' (aka UPLOD)\r\n'Thermactor Upstream Air Timer Min Load% Hysteresis' (aka UPLODH)" 030100 Address =0xB05A 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3B7A 000100 Cat0ID =0x7 030005 Title ="Power Steering Pressure Switch Present" 030011 DescSize =0x3B 030010 Desc ="PSPSHP - Set if power steering pressure switch is present." 030100 Address =0xA910 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x6A36 000100 Cat0ID =0x12 030005 Title ="Transient Fuel Compensation Switch" 030011 DescSize =0x69 030010 Desc ="TFCISW - Set if it is assumed the manifold wall is wet at start up, otherwise wall is assumed to be dry." 030100 Address =0xA507 030200 BitNumber =0x0 %%END%%